Electromagnetic Compatibility (Emc) - Scaleo medical Poweo 300 User Manual

Patient lifters
Table of Contents

Advertisement

Electromagnetic compatibility (EMC)

®
The Poweo
patient lifters require special care regarding the E.M.C. They must be installed
and commissioned considering the EMC information provided in this user manual.
The RF communication devices and portable phones may affect the Poweo
The use of accessories, transducers and cables other than those specified, except
transducers and cables sold by the manufacturer as replacement parts for internal
components, can result in increased emissions or decreased immunity of the device.
It is appropriate that the Poweo
with them, if it is not possible to do otherwise, the Poweo
normal operation in the configuration in which it is used.
In terms of the standard NF EN 60601-1-2: 2007, essential performance of the Poweo
never perform unwanted movements.
Directives and manufacturer's declaration - Electromagnetic emissions
The Poweo® is designed to be used in the electromagnetic environment specified below. The user of the Poweo® must make sure to use it in such
Emission test
Conformity
RF Emissions
Group 1
CISPR 11
RF Emissions
Class B
CISPR 11
Harmonic Emissions
Not applicable
IEC 61000-3-2
Voltage fluctuations /
Not applicable
Flicker IEC 61000-3-3
Recommended separation distances between portable and mobile RF communications equipment and the Poweo®
The Poweo® is designed to be used in an electromagnetic environment in which radiated RF disturbances are controlled. The user of the Poweo® can help
prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and
the Poweo®, as recommended below, according the maximum transmission power of the communication device.
Maximum rated
output power of the
transmitter
from 150 kHz to 80
W
0,01
0,1
1
10
100
DOMU124_EN_v2_20221206_Poweo® 300 User manual
®
patient lifter is not used next to other devices or stacked
environment.
Electromagnetic environment - Guidelines
The Poweo® uses RF energy only for its internal functions. Therefore, its RF emissions are very low
and are not likely to cause interference in nearby electronic devices.
The Poweo® is suitable for use in all premises, including domestic premises and those directly
connected to the public power network supplying domestic premises.
Separation distance depending on the frequency of the transmitter
80MHz to 800MHz
MHz
Non applicable
d= 0,35√P
Non applicable
0,04
Non applicable
0,11
Non applicable
0,35
Non applicable
Non applicable
®
must be monitored to verify
m
de 800MHz to 2,5GHz
1,1
3,5
®
lifters.
®
is to
d= 0,7√P
0,07
0,22
0,7
2,2
7
40

Advertisement