Locking the trigger switch
To lock the trigger switch:
1
► Release the trigger switch (2).
► Slide the retaining latch (1) to the
trigger switch.

16.3 Adjusting Operating Pressure and Flow Rate

To adjust the nozzle with the different flow rate, @ 23.2:
1
To increase operating pressure and flow rate spray:
► Turn rotary control (1) toward "Max."
To reduce operating pressure and flow rate:
► Turn rotary control toward "Min."
Operating pressure is indicated on the spray gun's pressure
gauge (2).
26
2
position to lock the
2

16.4 Adjusting the Nozzle

To adjust the nozzle with the different flow rate, @ 23.2:
A
For the full cone beam (A):
► Turn the nozzle as far as stop counterclockwise.
For the spot beam (B):
► Turn the nozzle one complete turn clockwise from the
closed position.

17 After Finishing Work

17.1 Preparing for Transportation or Storage

To prepare the sprayer for transportation or storage:
► Switch off the sprayer, @ 14.2.
► Remove the battery, @ 13.2.
► Squeeze the trigger switch to relieve any remaining the
pressure in the system, @ 16.2.
► Lock the trigger switch, @ 16.2.
► Drain the container in an environmentally responsible
manner, @ 16.1.2.
► Rinse the container with clean water.
► Fill the container with clean water, @ 16.1.1.
► Insert the battery, @ 13.1.
► Switch on the sprayer, @ 14.1.
17 After Finishing Work