22 Troubleshooting Guide

22 Troubleshooting Guide

22.1 Sprayer and Battery

Always remove the battery before carrying out any inspection, cleaning or maintenance.
Condition
LEDs on
Battery and
beeps on
Sprayer
Sprayer does not
start when switched
on.
1 LED flashes
green and 4
long beeps
sound.
1 LED glows
red.
4 LEDs flash
red and beeps
sound in quick
succession for
15 seconds.
3 LEDs glow
red.
3 LEDs flash
red.
Pump cuts out during
3 LEDs glows
operation.
red.
3 LEDs glow
red.
Run-time is too short.
0458-600-8221-A
Cause
Remedy
No electrical contact
► Remove the battery, @ 13.2.
between sprayer and
► Visually check the electrical contacts in the battery
battery.
compartment and on the battery.
► Reinsert the battery, @ 13.1.
Battery has low
► Charge the battery, @ 10.
charge.
Battery too hot / too
► Allow the battery to warm up or cool down gradually at
cold.
ambient temperatures of about 50 °F to 68 °F (10 °C to
20 °C).
Malfunction in
► Remove the battery and reinsert it, @ 13.
battery.
► Switch on the sprayer, @ 14.1.
► If the LEDs continue to flash, do not attempt to use.
The battery has a malfunction and must be replaced.
Sprayer too hot.
► Allow the sprayer to cool down.
Malfunction in
► Remove the battery and reinsert it, @ 13
sprayer.
► Switch on the sprayer, @ 14.1.
► If the LEDs still flash, do not attempt to use.
The sprayer has a malfunction and must be checked by a
servicing dealer.
Battery too hot / too
► Remove the battery, @ 13.2.
cold.
► Allow the sprayer and battery to cool down gradually at
Sprayer too hot.
ambient temperatures of about 50 °F to 68 °F (10 °C to
20 °C).
Battery not fully
► Charge the battery, @ 10.
charged.
English
33

Advertisement

Table of Contents
loading

Table of Contents