2
Enter the MCA self test access code (usually two or three digits as defined in
table IBNXLA).
Response:
The DN LCD flashes. MCA IS UNDER TEST appears on the DTE screen.
If the LCD does not flash, MCA IS UNDER TEST does not appear on the DTE
screen, and reorder tone is received continuously, the MCA self test could not
be set up. Check to ensure that the power source is properly connected.
Replace the handset, and try the MCA self test again at a later time. If
repeated attempts to set up the MCA self test fail, contact service personnel.
If confirmation tone is given and MCA TEST IS COMPLETE appears on the
DTE screen, the MCA circuit board is in working order. If there is a data
communications failure, the DTE, RS-232-C interface, or cable could be faulty.
If an audible reorder tone occurs for five seconds and MCA TEST IS
COMPLETE appears on the DTE screen, the MCA self test failed. The power
source may be disconnected. If the power source is securely connected,
contact service personnel to replace the MCA circuit board.
3
Replace the handset.
Response:
MCA self test completes. The test is over when the handset is replaced,
regardless of whether the test has been completed.
Note 1: If the HOLD key is pressed during the MCA self test, the test is over
regardless of whether the test has been completed.
Note 2: If the MCA self test has been set up, and no tone is received within 15
seconds, reorder tone is given followed by normal call treatment.
4
You have completed this procedure.
Table XLANAME
Table XLANAME (translation name) controls the addition and deletion of
translators to the IBN Translations table.
Each translator is assigned a one- to eight-character name plus the default
data. This default data is used for that translator name whenever an access
code is not specified in table IBNXLA.
Table 10-1 describes the fields to be entered. For more information on table
XLANAME, refer to the Commercial Systems Customer Data Schema,
555-4031-851, or Defense Switched Network Customer Data Schema,
555-4021-851.