This document is not part of any sales contract between Thermo Fisher Scientific Inc. and a purchaser. This document shall in no way govern or modify any Terms and Conditions of Sale, which Terms and Conditions of Sale shall govern all conflicting information between the two documents. Thermo Scientific Pacific Water Purification Systems...
Please consult your local sales representative for details. Warranty Thermo Electron LED GmbH warrants the operational safety and functions of the Thermo Scientific Barnstead Pacific water purification systems only under the condition that: • The system is operated and serviced exclusively in accordance with its intended purpose and as described in these operating instructions, •...
Page 5
• The serial number (located on the right side of the system on the nameplate) • The catalog number Thermo Scientific Pacific Water Purification Systems...
Additionally, the Pacific water purification system is in compliance with many other international standards, regulations and directives not listed here. Should you have any questions regarding compliance with national standards, regulations and directives applicable for your country, please contact your Thermo Fisher Scientific sales organization. Pacific Water Purification Systems Thermo Scientific...
Page 8
Unlocking the System..........57 Assignment table for persons authorized to unlock the system control... 58 Pacific Water Purification systems Thermo Scientific viii...
Page 9
Chapter 19 Maintenance Record ........97 Chapter 20 Contact Information Thermo Fisher Scientific ....99 Thermo Scientific Pacific Water Purification systems...
Page 10
Contents Pacific Water Purification systems Thermo Scientific...
Pacific water purification systems are carefully inspected and packed prior to shipping, but damage could still possibly occur during transport. Lifting and carrying the Thermo Scientific Barnstead Pacific water purification systems, e.g. to the installation location, should be carried out by two people.
Safety Precautions Observe these safety precautions for your own safety! The Thermo Scientific Barnstead Pacific water purification systems are modern water purification systems intended solely for the treatment of potable water. The water it produces is not save for drinking.
Page 14
Maintenance work on the system may only be performed by trained, authorized specialists. Do not pull the plastic foil over the head. Risk of suffocation. The plastic foil must to be used only for packaging the system and there components. Pacific Water Purification Systems Thermo Scientific...
Page 15
• Proceed as follows when the system has a defect: • Switch the system off and unplug the system from power outlet. • Shut off the feedwater supply. • Contact your local service organization. Thermo Scientific Pacific Water Purification Systems...
Page 16
Safety Precautions Pacific Water Purification Systems Thermo Scientific...
Each water system ships standard with the following items: • Pacific system that you have selected • Associated connection components (see contents of box table) • DI cartridge and • Storage tank that you have selected (purchase separately). Thermo Scientific Pacific Water Purification Systems...
1x Universal holder 21.1007 All TII/ TII UV, AFT, RO 1x DI cartridge 09.4001 All TII/ TII UV, AFT Compare the parts delivered as per the list above. Contact the manufacturer, if any part is missing. Pacific Water Purification Systems Thermo Scientific...
The system allows the purification of water into the water categories mentioned in the standards of ASTM 11.01 and ASTM 11.02. The Thermo Scientific Barnstead Pacific water purification systems are designed to be installed and use in the following application areas: •...
Page 22
Intended Use of the Device Pacific Water Purification Systems Thermo Scientific...
Silicate retention, % up to 99.9 up to 99.9 up to 99.9 up to 99.9 up to 99.9 Salt retention, % up to 98 up to 98 up to 98 up to 98 up to 98 Thermo Scientific Pacific Water Purification Systems...
Page 24
R3/4" Concentrate R3/4" Recirculation Ø6 mm/ 0.24 inch tube Pure water Ø8 mm/ 0.31 inch tube Water Connections of storage tank Pure water Ø8 mm/ 0.31 inch tube Recirculation Ø6 mm/ 0.24 inch tube Pacific Water Purification Systems Thermo Scientific...
Page 25
337 x 350 mm (13.21 x 13.78 inch) Weight empty 25 kg 25 kg 21 kg (46 lbs) Weight including DI cartridge and RO cartridge 27 kg (60 lbs) 27 kg (60 lbs) 23 kg (51 lbs) Thermo Scientific Pacific Water Purification Systems...
Page 26
Space to the back of the system at least 200 mm / 7.87 inch Top space at least 400 mm /15.75 inch Space to front of system Free accessibility Airborne sound emission Sound-pressure level 49 db(A) Pacific Water Purification Systems Thermo Scientific...
• An atmospherically floor drain with an outside diameter of 63 mm or 2.48 inch (DN 50 tube) shall be provided. • Unobstructed draining of the rinsing water to the drain must be ensured. Thermo Scientific Pacific Water Purification Systems...
Page 30
• Ample working space must be provided around the system for easy and pleasant replacement of wear and replacement parts and for ease of operation. • Easy access for operation and control of the system. Pacific Water Purification Systems Thermo Scientific...
6.3.1 of 61010-1 or 30 V r.m.s. and 42.4 V peak or 60 VDC and are electrically separated from hazardous live voltages by reinforced or double insulation. Pacific Water Purification Systems Thermo Scientific...
16. Cable for level control 17. D8 mm/ 0.31 inch tube quick connector pure water inlet (only Pacific AFT) Pacific TII and AFT have a recirculation connection on the systems panel. Recirculation is not applicable for RO. Thermo Scientific Pacific Water Purification Systems...
Use the second R¾” tube from the assembly kit to connect the „Concentrate” outlet of the system to the drain. Route the R3/4” tube with a free gravity fall to the drain. See “Mounting the Power Pack (Voltage Supply)” page Pacific Water Purification Systems Thermo Scientific...
Then use a 8 mm or 0.31 inch twist drill to make the holes and put in the four S8 plugs which are supplied with the wall mounting bracket. Mark up here the position for bore holes Wall Wall mounting bracket bottom part Thermo Scientific Pacific Water Purification Systems...
Page 36
M8 hexagon nuts onto the threaded bolts from the wall mounting bracket bottom part. Openings for screw on the hexagon nuts onto the wall mounting bracket bottom part Pacific Water Purification Systems Thermo Scientific...
Page 37
To prevent contamination of the 30L pure water tank when the lid is unscrew and mounting works, screw on the lid after you have placed the wall holder upper part on the pure water tank as described above. Thermo Scientific Pacific Water Purification Systems...
Page 38
Screws Wall mounting bracket After mounting the complete wall mounting bracket, connect the tubing and level control cable as described in the chapter “Connect a Pure Water Tank to the Pacific system” page 34 Pacific Water Purification Systems Thermo Scientific...
Then use a 8 mm or 0.31 inch twist drill to make the holes and put in the six S8 plugs which are Mark up here the supplied with the wall mounting bracket. positions for boreholes Wall Thermo Scientific Pacific Water Purification Systems...
Page 40
Place the 60L pure water tank with two people on the wall mounting bracket. Connect all tubings and wires as described in the section “Connect a Pure Water Tank to the Pacific system” page Pacific Water Purification Systems Thermo Scientific...
Screw hooks Dowels Lift the system and hang the back side of it onto the screw hooks. Screw hooks Lifting and carrying the system should be completed by in wall two people. Wall Backside system Thermo Scientific Pacific Water Purification Systems...
Page 42
Installation Figure 1 Holes for wall mounting Ø14 mm/ 0.55 inch 200 mm/ 7.87 inch Pacific Water Purification Systems Thermo Scientific...
The quick connectors are attached to the system in such a DI cartridge manner so as to prevent installing the DI cartridge incorrectly. DI cartridge Quick connectors Thermo Scientific Pacific Water Purification Systems...
O-ring Fitting Connect the control cable, coming from the tank, into the 4 pin plug of the connection panel on the system. Level control connection panel system Level control cable Open the feedwater tap. Pacific Water Purification Systems Thermo Scientific...
0.31 inch tube Connect the control cable, coming from the tank, into the 4 pin plug of the connection panel on the system. Level control connection panel system Level control cable Open the feedwater tap. Thermo Scientific Pacific Water Purification Systems...
O-ring Fitting Connect the control cable, coming from the tank, into the 4 pin plug of the connection panel on the system. Level control connection panel system Level control cable Open the feedwater tap. Pacific Water Purification Systems Thermo Scientific...
Rinse water tubing must be located at least 20 mm/0.75 inch above the drain. Attach the tubes in such a manner that they remain in their position. Minimum distance 20 mm/ 0.75 inch Drain Thermo Scientific Pacific Water Purification Systems...
Remove the protective foil on the back of the universal holder and from the universal adapter and attach the universal holder to the center of the back of the main adapter. Universal holder Universal foil Universal adapter Mains adapter Pacific Water Purification Systems Thermo Scientific...
Page 49
100 - 240V, 50-60 Hz power outlet. Power supply connection on the system Make sure that the power supply connector is always free accessible. (see Chapter 5 “Accessibility to Pacific systems and pure water tanks” page Thermo Scientific Pacific Water Purification Systems...
Page 50
Installation Pacific Water Purification Systems Thermo Scientific...
• Drain the first content of the storage tank to rinse out the preservation of the RO-membrane. • Depending on the Pacific system design and external storage tank, it could take between 2.5 and 10 hours to fill the storage tank. Pacific Water Purification Systems Thermo Scientific...
A level switch monitors the water level inside the tank. Permeate water can be dispensed from the pressurized external tank outlet (only systems with storage tanks and included pump) or from the front valve of the external tank. Thermo Scientific Pacific Water Purification Systems...
Page 54
How the Pacific Water Purification System Functions Pacific Water Purification Systems Thermo Scientific...
Sterile vent filter Drain Sterile overflow Pure water from pressurized tank outlet Pressure pump Pure water Storage reservoir: External 30L, 60L and 100L available with and without pump Purification flow Recirculation flow Waste water Thermo Scientific Pacific Water Purification Systems...
Sterile overflow Pure water from pressurized tank outlet Pressure gauge Pressure pump Pure water Storage reservoir: External 30L, 60L and 100L available with and without pump Purification flow Recirculation flow Waste water Emergency supply Pacific Water Purification Systems Thermo Scientific...
Booster pump Sterile vent filter Drain Sterile overflow Permeate from pressurized tank outlet Pressure pump Storage reservoir: External 30L, 60L Pure water and 100L available with and without pump Purification flow Waste water Thermo Scientific Pacific Water Purification Systems...
Page 58
Flow Chart Pacific Water Purification Systems Thermo Scientific...
Operating Elements Contents • “Description of Display Pacific TII, AFT” page 50 • “Description of Display Pacific RO” page 51 • “Flow Chart of Menu System Control” page 52 Thermo Scientific Pacific Water Purification Systems...
Settings for pure water/ permeate resistance Rinsing Operating hours UV-lamp (not active in RO versions) Pretreatment operating hours Disinfection (not active in Versions TII/ AFT and System faults display System faults print-output Unlocking the factory setting with your password Pacific Water Purification Systems Thermo Scientific...
Settings for pure water/ permeate resistance Rinsing Operating hours UV-lamp (not active in RO versions) Pretreatment operating hours Disinfection (not active in Versions TII/ AFT and System faults display System faults print-output Unlocking the factory setting with your password Thermo Scientific Pacific Water Purification Systems...
01:00 h OEM Menu Language English OEM Menu μS/cm - MΩ·cm μS/cm OEM Menu Temp. comp. OEM Menu Off: 100 % On: 85 % OEM Menu Version OEM Menu Type Pacific UPW S.No.: 9999/04 Pacific Water Purification Systems Thermo Scientific...
Limiting value setting range: 0.1 – 150.0 µS/cm Basic setting: 0.02 MΩ·cm With settings above 150.0 µS/cm, the limiting value is switched off and the word „Off” appears in the display. The display shows: Permeate 0.083 MΩ·cm Lim.val.permeate 50,0 µS/cm Pacific Water Purification Systems Thermo Scientific...
The limiting value for this operating time is set in the UV menu. The fault message that is displayed when the limiting value is exceeded is “Pretreatment”. The operating hours of the pretreatment are counted when the reverse osmosis pump is running. Thermo Scientific Pacific Water Purification Systems...
When the cleaning process has finished, the system returns to the last operating state (operation or stand-by) The remaining cleaning time is displayed while cleaning takes place. The display shows: Cleaning ? Press enter During cleaning, the display shows Cleaning 30 sec. Pacific Water Purification Systems Thermo Scientific...
An eighth press on the menu-key brings you to the “Code” menu. To prevent unauthorized access to the settings in the system control, changes to the settings can only be carried out when the correct code from the assignment Table that follows is entered and confirmed with Enter. The unlocking Thermo Scientific Pacific Water Purification Systems...
Using the arrow keys now allows a number from 0 to 9 to be entered at that position. A press on the menu-key takes you to the next menu point. The OEM-menu prompt display shows: OEM-Menu Press enter Pacific Water Purification Systems Thermo Scientific...
• Setting range: 1 – 50 °C The display shows: OEM-Menu max. Temp. 35 °C Disinfection Time A second press on the menu-key: (This function is not active in this system) The display shows: OEM-Menu Disinfect. Time 30 min. Thermo Scientific Pacific Water Purification Systems...
The rinse interval time is set in this menu. A rinse is carried out for this length of time when the operating state is changed, between stand-by and operation and every 12 hours. • Basic setting: 2 sec. • Setting range: 1 – 30 sec. Pacific Water Purification Systems Thermo Scientific...
• Setting range: 0.5 – 12 hours The display shows: OEM-Menu Send interval Language An eighth press on the menu-key: The language in which texts are to be displayed is set in this menu. Choice of English, German or French. Thermo Scientific Pacific Water Purification Systems...
• Specific electrical resistance µS/cm The display shows: OEM-Menu µS/cm / MΩ·cm MΩ·cm Switch off Temperature Compensation A tenth press on the menu-key: • Basic setting: On • Setting range: On, Off The display shows: OEM-Menu Temp. Comp. Pacific Water Purification Systems Thermo Scientific...
In this menu, the type and serial number of the system can be entered, both of which are then given as headline on every print-out. The following types of systems can be given: Pacific-RO, Pacific-TII, Pacific-TII UV, Pacific-AFT. The display shows: OEM-Menu Type Pacific AFT S.Nr.: 9999/04 Thermo Scientific Pacific Water Purification Systems...
Page 74
System Control Pacific Water Purification Systems Thermo Scientific...
UV lamp) months replaced. *Please keep in mind that the life of your consumable is directly dependent on the quality of the feed water and the amount of water used daily. Pacific Water Purification Systems Thermo Scientific...
Press on the two quick connectors at the inlet and outlet Quick of the DI- cartridge and remove the used DI cartridge. connectors DI cartridge We recommend performing a disinfection when an existing DI cartridge is replaced. DI cartridge Thermo Scientific Pacific Water Purification Systems...
Before start working on this, shut off the feedwater supply and switch the system off. Incorrect insertion of the reverse osmosis membrane would result in immediate damage to it. Step Action Figure Remove the back panel. Screws Locate the RO-module/ modules. Pacific Water Purification Systems Thermo Scientific...
Page 79
Do not reverse tubing connections or it could harm the RO membrane. Retaining d8 mm/ ring 0.31inch tube System with two RO-modules Retaining Rings Thermo Scientific Pacific Water Purification Systems...
Page 80
All Pacific models 3-12L, RO membrane 1x 22.0046 All Pacific models 20L, RO membrane 2x 22.0046 All Pacific models 40L, RO membrane 2x 22.0087 Pressure tube Wrong position of the RO-membrane into the pressure tube leads to immediate destruction of it. Pacific Water Purification Systems Thermo Scientific...
Page 81
Attach all d8 mm tubes with retaining rings back into the fittings on the RO- module/ modules. Open the feedwater supply and switch the system on. After membrane replacement, discard the first tankful of water as preservative has been rinsed from the membrane. Thermo Scientific Pacific Water Purification Systems...
After the Disinfection process, install new pretreatment filters and DI cartridges. Wear protective gloves for handling bleach disinfection solution. Wear safety goggles when working with bleach disinfection solution. During the disinfection process, the room should be well ventilated to prevent concentration of chlorine vapors. Pacific Water Purification Systems Thermo Scientific...
Page 83
“Adjusting the settings of the Float 15.5 °C UV/TC 15.5 °C UV/TC Switch” page Pacific TII using the tank with recirculation pump only: Adjust recirculation time in OEM menu to 30 minutes. “Recirculation Time” page Thermo Scientific Pacific Water Purification Systems...
Page 84
Remove disinfection adapter if added in step 1. Quick connectors DI For Pacific TII and AFT systems: replace DI cartridge (see “Replacing the DI cartridge (only Pacific TII/ TII UV, AFT)” page Disinfection adapter 50133431 Pacific Water Purification Systems Thermo Scientific...
Page 85
Chlorine test strips can be uses to test water for presence of residual chlorine. Repaet tank rinsing if necessary. After disinfecting the tank/recirculation always install new DI cartridges. Pacific TII and AFT systems, install a new DI cartridge after disinfection. Thermo Scientific Pacific Water Purification Systems...
Bumper PE Pipe d16x2mm Catalog no.: 14.0187 These bumpers are seating in the UV lamp housing Bumper O-ring Catalog no.: 21.5008 Change the UV lamp Never look directly into a switched-on UV lamp, as UV-light endangers eyesight! Pacific Water Purification Systems Thermo Scientific...
Page 87
UV lamp touching the glass of the UV lamp with fingers, to avoid dirtying of the lamp which would impair the UV lamp functioning of it. housing We recommend that clean gloves to be worn. Thermo Scientific Pacific Water Purification Systems...
Page 88
Once it is in place, re-mount the bracket holding the UV housing onto the system’s the mounting plate. Connection Sealing ring UV lamp UV lamp housing UV lamp UV lamp housing Pacific Water Purification Systems Thermo Scientific...
Page 89
The system sets the operating hours counter of the new UV lamp UV lamp back and save the new values by an press enter automatically calibration. The UV lamp must be switched on (production mode). Thermo Scientific Pacific Water Purification Systems...
Do not forget to re-adjust the pressure when you are returning the Pacific AFT system to the normal use. Step Action Figure Turn off system and water supply. ON/OFF switch Activate the emergency supply valve by turning it counter clockwise to the emergency supply position. Emergency supply valve Pacific Water Purification Systems Thermo Scientific...
Page 91
Do not forget to re-adjust the pressure when you are returning the Pacific AFT system to the normal use Increase Reduce pressure pressure Thermo Scientific Pacific Water Purification Systems...
Page 92
Maintenance Pacific Water Purification Systems Thermo Scientific...
Only specially trained personal can take the system out of operation and dispose it properly. If you have a used or broken UV lamp, contact your local Thermo Scientific service organization or waste disposal company. When the packaging is no longer needed it can be disposed of as household waste.
Page 94
Waste Disposal Pacific Water Purification Systems Thermo Scientific...
• Correct the language setting Error message: • Permeate conductivity too high • Check the pre-treatment “Lim. Val. Permeate“ • Limiting value set too low • Check and adjust the limiting value setting • Change the RO membrane Thermo Scientific Pacific Water Purification Systems...
Page 96
• System control defect • Replace the system control Error message: • Break in the measuring cell cable • Replace the measuring cell Meas. Cell LF3“, • System control defect • Replace the system control Pacific Water Purification Systems Thermo Scientific...
Please note that the use of spare parts, accessories or wear parts from other manufacturers will nullify the warranty for this unit. Contents • “Replacement Parts for Pacific systems” page 88 • “Replacement Parts for Optional Storage Tank” page 89 Thermo Scientific Pacific Water Purification Systems...
Tabletop power pack 24VDC 180W (not shown) 50151559 All TII/ TII UV, AFT, RO 20 AFT 20-40 Relais 24V 30 A 50151551 All TII/ TII UV, AFT, RO Replacement Parts for Optional Storage Tank Thermo Scientific Pacific Water Purification Systems...
Page 100
Float switch for 100 L storage tank 16.0402 All TII/ TII UV, AFT Female quick connect coupling 14.0009 All AFT Male quick connect coupling 16.0006 All AFT Check valve 15.0009 All TII/ TII UV, AFT Pacific Water Purification Systems Thermo Scientific...
[MΩ·cm] prefilter Last Last Operating Notes Signature change of disinfection hours hardness stabilizer The following point should be observed for maintenance of the quality of the system: • 1x / Weekly, acquire measured values. Thermo Scientific Pacific Water Purification Systems...
Page 108
Maintenance Record Pacific Water Purification Systems Thermo Scientific...
Contact Information Thermo Fisher Scientific Contact address for service: Overview of Thermo Scientific international sales organization Postal address in USA: Thermo Scientific 275 Aiken Road Asheville, NC 28804 Inquiries from USA/Canada +1 866 984 3766 Sales: +1 800 438 4851...
Page 110
2016 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Pacific Water Purification Systems Thermo Scientific...
Page 111
(Tank Quality) 13 Examination on Receipt 2 Programme Choice, TII/TII UV, RO 63 Explanatory Notes on the Operating Instructions iv Pure Water Limiting Value 55 Extend of Delivery 7 Putting the System into Operation 42 Thermo Scientific Pacific Water Purification Systems...
Page 112
Real Time clock 61 Recirculation Time 60 Replacement Parts 87 Replacement Parts for Optional Storage Tank 89 Replacement Parts for Pacific systems 88 Replacing the DI cartridge 67 Rinse Interval Time 60 Rinsing Time 60 Safety Precautions 3 Sending Interval 61 Standards and Directives vi Structure of the UV lamp 76 Switch off Temperature Compensation 62...