6.16 Priming:
Never operate pump with inlet and/or outlet isolating valves in the
closed position. Damage will occur!
The tank must be filled with water before starting the pump.
(a) Turn on the service valves nearest the iBoost and allow the air to vent
from the system.
(b) Turn on the iBoost and allow the pump to build up pressure purging the
air from the system..
(c) Open all the service valves (including flushing WCs) in turn to fully purge
the air from the system.
6.17 Starting:
a) Ensure all outlets are closed, turn power supply 'on' – pump will start,
pressurise the system then stop.
b) Open and close all outlets in turn associated with the pump, (including
w/c systems) allowing water to flow from each outlet until all air is
purged. As each outlet is opened and closed, the pump will start and stop
respectively.
Note: After closing the outlet there will be a small time delay before the
pump stops, which is normal.
c) Any tap or control valve within the system when opened and closed will
now turn the iBoost on/off, there will be a delayed start due to the water
stored in the pressure vessel. Providing this is the case the system is now
operating correctly.
d) Carefully check pump and pipework for leaks whilst pump running and
stationary before leaving the installation unattended.
6.18 For Further Technical Support: Phone the Stuart Turner TechAssist team
on +44 (0) 800 31 969 80. Our staff are trained to help and advise you over
the phone.