Table of Contents

Advertisement

G4PB8, G4PB16, G4PB24
The 50-pin headers on these opto racks do not connect pin-49 to the supply input for the modules. The
user will have to supply 5 VDC to the terminal marked LOGIC (+) on the rack. This can be
accomplished by simply running a single lead from the Galil 5 V supply to LOGIC (+) [note: the (-)
return is already connected by the header].
G4PB8H, G4PB16H
The 50-pin headers on these racks actually connect both pin-49 and pin-1 to the logic supply. The user
does not have to supply 5 V; however, pin-1 of the ribbon cable MUST be cut to avoid damage. Pin-1
leads to an actual unused I/O channel on the Galil and damage will occur to the extended I/O board if
the 5 V line is left connected.
G4PB32H, G4PB32DEC
These 32 channel opto racks are NOT compatible with Galil extended I/O headers. Damage may occur
if the connection is made with Galil extended I/O headers. The pinout configurations are laid out for a
specific DEC computer interface and PAMUX B4 brain boards.

Pinout

J1 – 40 Digital I/O (50-Pin IDC Header)
1 Bank 4 – Bit 40
3 Bank 4 – Bit 39
5 Bank 4 – Bit 38
7 Bank 4 – Bit 37
9 Bank 4 – Bit 36
11 Bank 4 – Bit 35
13 Bank 4 – Bit 34
15 Bank 4 – Bit 33
17 Bank 3 – Bit 32
19 Bank 3 – Bit 31
21 Bank 3 – Bit 30
23 Bank 3 – Bit 29
25 Bank 3 – Bit 28
27 Bank 3 – Bit 27
29 Bank 3 – Bit 26
31 Bank 3 – Bit 25
33 Bank 2 – Bit 24
35 Bank 2 – Bit 23
37 Bank 2 – Bit 22
39 Bank 2 – Bit 21
41 Bank 2 – Bit 20
43 Bank 2 – Bit 19
45 Bank 2 – Bit 18
47 Bank 2 – Bit 17
49 5 V
96 • Appendices
2 Bank 5 – Bit 41
4 Bank 5 – Bit 42
6 Bank 5 – Bit 43
8 Bank 5 – Bit 44
10 Bank 5 – Bit 45
12 Bank 5 – Bit 46
14 Bank 5 – Bit 47
16 Bank 5 – Bit 48
18 Bank 6 – Bit 49
20 Bank 6 – Bit 50
22 Bank 6 – Bit 51
24 Bank 6 – Bit 52
26 Bank 6 – Bit 53
28 Bank 6 – Bit 54
30 Bank 6 – Bit 55
32 Bank 6 – Bit 56
34 GND
36 GND
38 GND
40 GND
42 GND
44 GND
46 GND
48 GND
50 GND
CDS-3310