Error Code 42
Unable to Print 42
Head voltage does not turn OFF.
User Check
- They may occur due to lower surrounding temperature. Use in warmer surrounding
temperature.
Step
1
Head flat cable connection
failure
2
Carriage flat cable connection
failure
3
Carriage PCB defective
4
Head defective
5
Power supply PCB defective
6
Main PCB defective
Error Code 43
Unable to Print 43
Head thermistor defective
Head thermistor detects -20 degree-C or less and 80 degree-C or more when power is
on.
Step
1
Carriage flat cable connection
failure
2
Head thermistor defective
3
Main PCB defective
Cause
Reconnect the head flat cable.
Reconnect the Carriage flat cable.
Replace the carriage PCB ASSY.
Replace the head/carriage unit.
Replace the power supply PCB.
Replace the main PCB ASSY.
Cause
Reconnect the Carriage flat cable.
Replace the head/carriage unit.
Replace the main PCB ASSY.
2-35