Figure 7-24 Connecting cables
Step 3 Connect the other end of the power cable to the DC PDU in the cabinet.
The DC PDU is fastened horizontally in the rear of the cabinet. Connect the power
cable to the socket on the PDU according to the plan.
Step 4 Bundle the power cables to the cable guide using cable ties.
----End

7.2.6.8 Checking Cable Connections

Before checking cable connections, ensure that the power is cut off. Otherwise,
any incorrect connection or loose connection may cause human injury or device
damage.
Table 7-3 Cable connection checklist
Item
Power cable
Network cable
Issue 04 (2020-06-05)
Insert the power cables to the wiring terminals on the PSU until the cables
click into position. See (2) in
Connect the cord end terminal of the negative power cable (blue) to the
NEG(-) wiring terminal on the PSU.
Connect the cord end terminal of the positive power cable (black) to the
RTN(+) wiring terminal on the PSU.
Copyright © Huawei Technologies Co., Ltd.
Figure
7-24.
Description
Power cables are correctly connected to the rear of the
chassis.
Network cables are connected correctly to the
management port or service ports on the rear panel of
the chassis.