Technical Data - Siemens VersiCharge AC Installation And Operation Manual

Electric vehicle charging station
Hide thumbs Also See for VersiCharge AC:
Table of Contents

Advertisement

VersiCharge™ AC Installation and Operations Manual
VersiCharge™ AC series – Technical Data
Features and functions
Charging mode
Vehicle connection
AC power output
Mounting options
Touch button
Charging status LEDs
Communication status LEDs
Parent / child network
Load management
Communication
Interfaces
User authentication
Configuration
Back-end protocol
Software upgrade
Electrical design
Power supply voltage
Rated current settings (A)
Crosswire section
Network type
Energy metering
Ground fault protection
Over voltage protection
Over current protection
Operating altitude
General design
Environmental rating
Dimensions (H x W x D)
Weight
Ambient conditions
Colors
Certificates and standards
cUL listed
EMC
Maximum
current
40 A
Residential
Smart
version
48 A
40 A
Child
Commercial
48 A
versions
40 A
Parent
48 A
Buy
Child
48 A
American
Commercial
Parent
48 A
versions
Back-end protocol: OCPP 1.6, upgradeable to OCPP 2.0.1
Data plans, accessories and bundled packages for chargers: Siemens offers chargers with data plans, posts and bundled solutions for customer
convenience. See table below:
Description
Multi-carrier pooled data plan: 1-year data plan, 1 GB capped monthly bandwidth (supports one parent charger and one
child charger). This is an annual fee.
Extended warranty per Level 2 charger: 1 additional year, no in / out services
Extended warranty per Level 2 charger: 2 additional years, no in / out services
Standard post: can support one or two chargers. Comes with installation kit, made of aluminum. Includes 1-year warranty.
Standard post cable retraction unit: used with US2:VCPOSTGRY2 post design. One required for each charger. Includes
1-year warranty.
40
Level 2
J1772 plug with 20-foot cable, 40 A / 48 A / integrated cable management
Single phase up to 9.6 kW (40 A) - requires a 50 A breaker, or 11.5 kW (48 A) - requires a 60 A breaker
Wall and post mounting, see accessories
Time delay, return to maximum power level, reset ground fault
Power, time delay, charging state, reduced power level, authentication, cold start
Connected / not connected during operation, signal strength during commissioning
Connects to one child charger by Wi-Fi within 20 feet line of sight
Via OCPP
Ethernet, Wi-Fi, for parent units additionally LTE, WCDMA
RFID (local Whitelist, MIFARE)
Via Siemens mobile app or the PC Configuration Tool
OCPP 1.6, upgradeable to OCPP 2.0.1
Over-the-air (OTA)
Single phase: 208 V / 240 V AC, 60 Hz
12, 16, 24, 32, 40, 48
Single phase: 8 AWG / 6 AWG (90 °C rated wire)
Single phase / split phase
Embedded metering, +/- 1% accuracy
20 mA
Under voltage: 167 V (minimum 80 V) / over voltage: 267 V (maximum 275 V)
Current +10% above configured threshold, minimum +2A, 5 seconds
9,840 ft
Indoor and outdoor, NEMA 4, IK 8
16.10 in x 7.09 in x 3.78 in
17 lbs
Operating temperature: -31 °F to +122 °F, storage temperature: -40 °F to +140 °F, 98% non-condensing
Silver metallic (Pantone 10077), black holster
According to UL 1998, UL 991, UL2594/CSA C22.2 No.280/NMX-J-677-ANCE, UL 2231-1/CSA C22.2 No.281.1/
NMX-J-668-1, UL 2231-2/CSA C22.2 No.281.2/NMX-J-668/2-ANCE, UL 2251/CSA C22.2
No.282/NMX-J-678-ANCE
FCC Part 15 Class A
Wi-Fi and
Model number
Ethernet
8EM1312-4CF18-0FA3
8EM1312-5CF18-0FA3
8EM1310-4CF14-0GA0
8EM1310-5CF14-0GA0
8EM1310-4CF14-1GA2
8EM1310-5CF14-1GA2
8EM13155CG140GF0
8EM13155CG141GF2
RFID
Embedded
identification
metering
LTE
Installed
WCDMA
SIM card
Catalog Number
US2:DATA1YRMULTI
US2:VCEXWAR1YR
US2:VCEWAR2YR
US2:VCPOSTGRY2
US2:VCCMSSP