P3 is power assist control mode setting, when P3 parameter setting is1, power assist
control mode is gear 5 of "imitation torque control" mode, when P3 parameter setting is
0, power assist control mode is gear 5 of "speed control" mode. P3 parameter needs to be
determined according to the distributed function of the controller, its setting range is 0 or 1,
press
button (UP) or
method is the same to that of P2.
P4 Handlebar Startup Setting
Enter P4 parameter setting interface, P4 parameter column flashes.
P4 is handlebar startup setting, when P4 setting is 1, indicating the handlebar is under
"non-zero startup" mode, namely, the handlebar can be effective only after startup the
foot power assist. When P4 setting is 0, indicating the handlebar is under "zero startup"
mode, the motor can be startup by the handlebar directly. P4 setting range is 0 or 1, press
button (UP) or
the same to that of P2.

P5 Power Monitoring Setting

Enter P5 parameter setting interface, P5 parameter column flashes.
P3 parameter setting interface
button (DOWN) for selection. P3 parameter setting
P4 parameter setting interface
button (DOWN) for selection. P4 parameter setting method is
- 22 -