ELECTRIC BICYCLE METER KT—LCD10H Product User Manual
Error Code
01_info
03_info
04_info
05_info
06_info
Motor operating temperature alarm:
Under any interface, when the motor operating temperature exceeds the warning value,
the motor operating temperature display flashes to alarm, meanwhile, the controller will
offer the appropriate protection to motor.
User Setting Project
KT-LCD10H meter user setting project:

General project setting

P parameter setting
C parameter setting
L parameter setting
General Project Setting

Maximum Trip Speed

Under power off status, hold
5 seconds after boot-up, hold
simultaneously for about 2 seconds, the first is to enter the maximum riding speed setting
interface, then the speed display column flashes. Press
(DOWN) in order to set the maximum riding speed value. The default maximum riding
speed value was 25Km/h. When the speed of the electric vehicle exceeds the set value,
the motor will be stopped driving.
Motor Hall Signal Abnormality
Torque sensor Signal Abnormality
Axis speed sensor Abnormality(only applied to torque sensor )
Motor or controller has short circuit Abnormality
Definition
Throttle Abnormality
button long (SW), the meter is turned on. Within
button (UP) and
- 17 -
button (DOWN)
button (UP) or
button