2. If the event persists, reset BMC to default setting to trigger inventory power calculation again.
3. If the event persists, ensure the indicated compute node is completely power off, and then reseat it.
(Service technician only)
4. If the event persists, replace the indicated compute node. (Service technician only)
5. If the event persists, please consult with technical service.
• 21050133: Node 12 Invntory: Slot Or Connector, Limit Exceeded was asserted.
The BMC on indicated compure node reports an invalid inventory power whose minimum value higher
than the maximum value.
Severity: Warning
Alert Category: Node - Node event
SNMP Trap ID: 553976115
User Action:
1. Reset the BMC on indicated compute node.
2. If the event persists, reset BMC to default setting to trigger inventory power calculation again.
3. If the event persists, ensure the indicated compute node is completely power off, and then reseat it.
(Service technician only)
4. If the event persists, replace the indicated compute node. (Service technician only)
5. If the event persists, please consult with technical service.
• 21070134: Node 1 Power Cap: Slot Or Connector, transition to Non-Critical from OK was asserted.
The power capping setting restored to indicated compute node is lower than the boundary of its inventory
power.
Severity: Warning
Alert Category: Node - Node event
SNMP Trap ID: 554107188
User Action:
Configure new power capping setting to indicated compute node through web GUI or OEM IPMI
command.
• 21070135: Node 2 Power Cap: Slot Or Connector, transition to Non-Critical from OK was asserted.
The power capping setting restored to indicated compute node is lower than the boundary of its inventory
power.
Severity: Warning
Alert Category: Node - Node event
SNMP Trap ID: 554107189
User Action:
Configure new power capping setting to indicated compute node through web GUI or OEM IPMI
command.
• 21070136: Node 3 Power Cap: Slot Or Connector, transition to Non-Critical from OK was asserted.
The power capping setting restored to indicated compute node is lower than the boundary of its inventory
power.
Severity: Warning
Alert Category: Node - Node event
SNMP Trap ID: 554107190
User Action:
54