Lenovo ThinkSystem DW612S Neptune DWC Instructions Manual page 14

Smm 2 messages and codes reference
Hide thumbs Also See for ThinkSystem DW612S Neptune DWC:

Advertisement

Severity: Information
Alert Category: System - SMM2 system event
SNMP Trap ID: 33621769
User Action:
1. Virtual reset SMM2 via Web GUI or IPMI command.
2. If the event persists, ensure all populated compute nodes are completely power off, then reseat
SMM2 module. (Service technician only)
3. If the event persists, ensure all populated compute nodes are completely power off, then replace the
SMM2 module. (Service technician only)
4. If the event persists, please consult with technical service.
• 0201070A: SMM2 Brd 2.5V: Voltage sensor, warning event was asserted, reading value %V
(Threshold %V)
Asserted when voltage sensed on 2.5V power rail is higher than upper non-critical threshold.
Severity: Information
Alert Category: System - SMM2 system event
SNMP Trap ID: 33621770
User Action:
1. Virtual reset SMM2 via Web GUI or IPMI command.
2. If the event persists, ensure all populated compute nodes are completely power off, then reseat
SMM2 module. (Service technician only)
3. If the event persists, ensure all populated compute nodes are completely power off, then replace the
SMM2 module. (Service technician only)
4. If the event persists, please consult with technical service.
• 0201070B: SMM2 Brd 3.3V: Voltage sensor, warning event was asserted, reading value %V
(Threshold %V)
Asserted when voltage sensed on 3.3V power rail is higher than upper non-critical threshold.
Severity: Information
Alert Category: System - SMM2 system event
SNMP Trap ID: 33621771
User Action:
1. Virtual reset SMM2 via Web GUI or IPMI command.
2. If the event persists, ensure all populated compute nodes are completely power off, then reseat
SMM2 module. (Service technician only)
3. If the event persists, ensure all populated compute nodes are completely power off, then replace the
SMM2 module. (Service technician only)
4. If the event persists, please consult with technical service.
• 0201070C: SMM2 Brd 5V: Voltage sensor, warning event was asserted, reading value %V
(Threshold %V)
Asserted when voltage sensed on 5V power rail is higher than upper non-critical threshold.
Severity: Information
Alert Category: System - SMM2 system event
SNMP Trap ID: 33621772
User Action:
1. Virtual reset SMM2 via Web GUI or IPMI command.
10
ThinkSystem DW612S Neptune DWC Enclosure SMM 2 Messages and Codes Reference