Specifications and reference data
October 2022
A.2.6
Configuration
IO-Link configuration tools
Examples:
•
Rosemount IO-Link Assistant (available as accessory)
•
FDT
Damping
User selectable (default is 2 s, minimum is 0 s)
Output units
•
Level: in., m
•
Temperature: °F, °C
•
Volume flow: US gal/h, m
•
Signal strength: mV
Output variables
Variable
Level
Distance (ullage)
Volume flow
Electronics temperature N/A
Signal strength
Volume flow calculations
•
Linearization table
•
Parshall flume
•
Khafagi-Venturi flume
A.2.7
Process pressure
-15 to 43.5 psig (-1 to 3 bar)
Note
The PE100 flanges must be used only in non-pressurized applications.
74
®
frame applications, e.g. PACTware
3
/h
4-20 mA
✓
N/A
✓
N/A
DO1 and DO2
Digital, service
tools using
IODD
✓
✓
✓
N/A
✓
✓
✓
N/A
✓
N/A
Rosemount 1208A Level and Flow Transmitter
Reference Manual
00809-0100-7062
IO-Link PDIn
(to the PLC)
✓
N/A
✓
N/A
N/A