OBD10M-R2000-4EP-V1V17
Commissioning
Manual IP
You can also address the sensor via an IP address set manually. You can set the
PC network card and the sensor to an IP address of your choice.
Note
The IP address of the sensor is set to 10.0.10.9 and the subnet mask to 255.0.0.0
by default.
Configuring a Connection via a Manual IP Address
1.
Configure the sensor:
1. Under Ethernet Setup > Address Mode, set the sensor to "Manual."
2. Enter the required address under Ethernet Setup > IP Address.
3.
Restart the sensor to apply the configuration.
4.
To connect the sensor to the PC, enter the required IP address in the menu for the
PC network card. Select the TCP/IP protocol in the PC network card properties.
5.
Select "Use the following IP address" and enter the required IP address and
subnet mask.
13