Slip Mtu - Motorola iM1000 User Manual

Data modem
Hide thumbs Also See for iM1000:
Table of Contents

Advertisement

Change the DCE's PIN
This command sets the PIN that locks or unlocks the DCE.
Note that you must specify the desired PIN, as well as the
current PIN. The factory-default PIN is the
or a value of
Action
+WCPN
Query
Range
Parameter Values:
A PIN is stored as a series of alphanumeric characters, with
a maximum length of 8 characters. If more than 8
characters are set as a PIN, only the first 8 are recognized.
Packet Data Sleep Timer
This timer controls the length of time the DCE stays on a
packet channel while there is no traffic actively being
transferred.
Action
Query
+WS175
Range
Parameter Values:
0
5-255
10

SLIP MTU

This setting specifies the Maximum Transmitted Unit used
by SLIP connections. (PPP connections negotiate this
value.)
Action
+WV312
Query
Range
Parameter Values:
68-1500
1006
ÒÓ
.
AT+wcpn=<newPIN>,<oldPIN>
AT+wcpn=?
AT+ws175=<timer>
AT+ws175?
AT+ws175=?
Disable sleep timer
Seconds before sleeping
Default value
AT+wv312=<MTU>
AT+wv312?
AT+wv312=?
MTU Value Range
Default value
Appendix
Ò
Ó
empty string
,