Circuit Data Establishment Timeout; Circuit Data Idle Timer - Motorola iM1000 User Manual

Data modem
Hide thumbs Also See for iM1000:
Table of Contents

Advertisement

Circuit Data Establishment Timeout

This command allows the DTE to specify the maximum
amount of time between a request for a circuit data
connection and the establishment of this connection.
Action
S7
Query
Range
Parameter Values:
1-255
120
Comma Dial Modifier Timer
This command allows the DTE to set the duration of the
pause associated with a comma (,) dial modifier.
Action
Query
S8
Range
Parameter Values:
0-255
2

Circuit Data Idle Timer

This command specifies an idle line timeout for online data
mode. If no data is sent by the DTE on the transmit data line
for the specified period of time, the DCE disconnects the
call, returns the OK result code, and returns to command
mode.
Action
S30
Query
Range
Parameter Values:
0-255
0
ATs7=<timer>
ATs7?
ATs7=?
Seconds
Default value
ATs8=<timer>
ATs8?
ATs8=?
Seconds
Default value
ATs30=<timer>
ATs30?
ATs30=?
Seconds
Default value