Table 8: Supported S-Registers
Register #
3
Command Line Terminating Character. Specifies the
ASCII character to be used to terminate a command
line without carrying out any command that might be
issued.
The valid range of values is 0 (zero) to 127. The
default is 13, which represents the Enter (PC-
compatible) or Return (Macintosh) key.
4
Response Format Character.
The valid range of values is 0 (zero) to 127. The
default is 10 or the ASCII
5
Command Line Editing Character.
The valid range of values is 0 (zero) to 127. The
default is 8 or the Backspace key.
6
Pause Before Blind Dialing.
The valid range of values is 2 to 10. The default is 2,
or 2 seconds.
7
Connection Completion Timeout.
The valid range of values is 1 to 255 seconds. The
default is 120 seconds.
8
Command Dial Modifier Time.
The valid range of values is 0 (zero) to 255 seconds.
The default is 2 seconds.
10
Automatic Disconnect Delay. Determines the amount
of time between loss of carrier and disconnection of
the data call.
The valid range of values is 1 to 254 tenths of a
second. The default is 14, or 1.4 seconds.
12
Escape Code Timer. Determines the time duration
within which the escape code must be sent by the
computer to escape from online mode to command
mode.
The valid range of values is 20 to 255. The time (in
seconds) that the modem waits is determined by
dividing the specified register value by 50. The default
is 50 (that is, 50/50) or 1 second.
Appendix
Function
Ò
Ó
Linefeed
character.