Connectors - PROEMION CANlink mobile 3000 Series Device Manual

Hide thumbs Also See for CANlink mobile 3000 Series:
Table of Contents

Advertisement

4.2. Connectors

The device is equipped with the following connectors:
• 1 main plug connector (14-pin): CAN1 / CAN2 / VCC / GND / AIN1-3 / DOUT / CAN3
• 1 GNSS antenna port, FAKRA, C-coded in blue (types 3351, 3373, 3377, 3477, 3577, 3651, 3673, 3677)
• 1 mobile radio antenna port, FAKRA, D-coded violet (types 3351, 3373, 3377, 3477, 3577, 3651, 3673, 3677)
• 1 micro-USB port, type AB
NOTICE
According to the manufacturer's information, the connectors are equipped for the following
minimum number of mating cycles:
Main plug connector: 10 cycles
Fakra plug: 100 cycles
Micro USB: 1000 cycles
If the minimum number of mating cycles is exceeded, individual parameters could lie outside
those in the specification.
4.2.1. Main Plug Connector
Use the main plug connector to connect the device to the CAN bus and supply it with power. The I/O signals are
integrated in the plug connector.
NOTICE
The main plug connector contains a reset button. The Reset button is required to complete local
firmware updates or to switch the device off in the case of types with an integrated, rechargeable
battery.
NOTICE
The main plug connector is designed for a minimum number of 10 mating cycles.
If the minimum number of mating cycles is exceeded, individual parameters could be out of the
specification. The basic function of the main plug connector remains intact. Please be aware that
the process of the CANlink mobile system integration is not designed for a high number of mating
cycles. Ideally the device is configured with an adapter cable from the
instance and in the second step installed and cabled within the machine.
INFORMATION
The pin assignment shown here can vary depending on the type. The types 3311, 3351 and 3355
do not have a CAN2 interface. The types 3611 and 3651 have no CAN2 and CAN3 interface.
INFORMATION
The analog inputs operate in a range of 0 VDC to 15 VDC. Optionally, you can use the input as a
digital input with a maximum voltage of 36 VDC. The digital output switches to supply voltage on
terminal 30 and can only take a maximum load of 500 mA. Provide an external safeguard if this
limit is not ensured by the external terminal 30 power supply. Input terminal 15 detects "high" from
a voltage of 5.5 V and "low" below a voltage of 2.3 V.
CANlink mobile 3000 Device Manual
Launch Kit
in the first

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents