Table 26 Fuser operating temperatures
Environment (1st print-5 min / 5 min-10 min / 10 min +)
Machine State or Paper
Type
LL
Machine in standby
170 deg C
Plain
187/183/178 deg C
Thick
200/195/195 deg C
OHP
175 deg C
Thin
185/180/175 deg C
Cardstock
204/200/200 deg C
Envelope
200/195/195 deg C
The environment acronyms are as follows:
LL - Low temperature/low humidity.
NN - Normal temperature/normal humidity.
HH - High temperature/high humidity.
Table 27 HVPS Output
HVPS Output
Transfer High Voltage (THV)
Transfer Cleaning Voltage (THV Neg)
Developing Voltage (DEV)
Charge Voltage (MHV)
Supply Voltage
Blade Voltage
OPC Drum
General Procedures and Information
GP 11
NN
HH
170 deg C
165 deg C
185/178/173 deg C
175/170/165 deg C
195/190/190 deg C
195/190/190 deg C
165 deg C
165 deg C
180/180/175 deg C
180/175/170 deg C
204/200/200 deg C
200/195/195 deg C
195/190/190 deg C
190/190/190 deg C
Voltage
+1300V +/- 20V
-1000V +300V/-150V
-450V +/- 20V
-1350V +/- 50V
-600V +/- 50V
-500V +/- 20V
-135V +/- 15%