Parameters; Sweep Trigger Mode; Marker Out Behaviour In Sweep Run Mode - Teledyne T3AWG3K Series Operator's Manual

Hide thumbs Also See for T3AWG3K Series:
Table of Contents

Advertisement

Operator's Manual Simple AFG Application
Logarithm: the frequency increases and decreases following a logarithmic function.
Upstair: the frequency varies step by step. The number of steps is selectable through the Step
Number parameter.
Arbitrary: allows to load a sweep profile from a file. By default, the "Arbitrary" waveform is a
cosine function. As Carrier Arbitrary you can select the waveform by combo box Waveform List.
Note: the time to execute the sweep is the sum of Rising, Holding and Falling Time. When the
User Defined mode is selected these 3 parameters are not meaningful.

Parameters

Rising Time [s]: it controls the time to increase the frequency from the Start Frequency up to
the Stop Frequency.
Holding Time [s]: it is the time that the frequency keeps the Stop Frequency.
Falling Time [s]: it controls the time to decrease the frequency from the Stop Frequency back to
the Start Frequency.
Note: the time parameters must meet the following conditions:
������������ �������� + �������������� �������� + �������������� �������� ≤ 2000 ��
Step Number [N]: it selects the number of frequency steps of the Upstair Sweep mode.
Start Frequency [Hz]: it selects the initial sweep frequency.
Stop Frequency [Hz]: it selects the final sweep frequency.

Sweep Trigger Mode

Repeat: the instrument starts when the Run/Stop button is pressed and repeats the sweep
continuously. The maximum marker's skew is about 14s.
Trigger: When the Run/Stop button is pressed the instrument waits for a Trigger signal. When
the trigger is detected, it generates the sweep profile then stops waiting for a new Trigger.
During the wait for a Trigger the instrument generates the waveform with its frequency equal to
the start frequency. The maximum marker's skew is about 3us

Marker Out behaviour in Sweep Run Mode

In this Run Mode the Marker Out generates a square wave with the rising edge placed at the beginning
of each sweep and the marker's period is equal to the sum of Rising Time, Holding Time and Returning
Time parameters.
62

Advertisement

Table of Contents
loading

This manual is also suitable for:

T3awg325xT3awg335x

Table of Contents