Operator's Manual Simple AFG Application
Is Enabled
Marker Skew [s]
(Run Mode Contin. or
Modul)
Marker Skew [s]
(Run Mode Burst or
Sweep Trig.)
Link To
It enables or disables the Marker Out. When the Marker Out is disabled, it
is forced to 0 V.
It sets the delay between the marker and the analog channel. This
parameter is valid only if the run Continuous Mode or Modulated Mode
or Sweep Repeated Mode is been selected for the associated channel to
the Marker out.
The skew range is 0s to 14s.
It sets the delay between the marker and the analog channel. This
parameter is valid only if the run Sweep Triggered Mode or Burst Mode is
been selected for the associated channel to the Marker out.
The skew range is 0s to 3us.
Since there is one Marker Out signal for each couple of analog channels,
using this parameter it is possible to choose which analog channel is
related to the Marker Out N signal.
Please note that
•
Marker Out 1 can be linked to Channel 1 or Channel 2
•
Marker Out 2 can be linked to Channel 3 or Channel 4
•
Marker Out 3 can be linked to Channel 5 or Channel 6
•
Marker Out 4 can be linked to Channel 7 or Channel 8
73