Installation; Multi Mode; Single Mode; Fiber Cable - Transition Networks E-TEL-1200 User Manual

100base-tx/100base-fx multi-port media converter
Table of Contents

Advertisement

INSTALLATION

Install E-TX-FX-xx00 at Site
WARNING: During the site installation, handle the E-TX-FX-xx00 in such a
way that the E-TX-FX-xx00 does not fall. Failure to observe this warning
could result in injury to personnel and/or equipment damage.
To install the E-TX-FX-xx00 in 19-inch rack cabinet:
NOTE: Brackets and screws are provided.
1
TP LINK
1
TP LINK
2
FBR LINK
FBR LINK
POWER
ACT
ACT
ACT
3
1.
Install right and left mounting brackets to E-TX-FX-xx00 chassis by
removing two (2) screws from each side of E-TX-FX-xx00 chassis
and then installing those screws through mounting bracket into E-
TX-FX-xx00 chassis.
2.
Carefully align the E-TX-FX-xx00 between rack mounting rails.
3.
Install E-TX-FX-xx00 in rack by installing two (2) screws through
right front bracket into rack and two (2) screws through left front
bracket into rack, using clip nuts (NOT provided) if necessary.
To install the E-TX-FX-xx00 on table or other flat surface:
NOTE: Rubber feet are provided.
1.
Carefully turn E-TX-FX-xx00 to side.
2.
Install four (4) rubber feet:
Separate rubber feet.
Remove protective
paper from adhesive
surface on rubber foot.
Position and secure
each rubber foot as
shown.
3.
Return E-TX-FX-xx00 to upright position.
2
TP LINK
3
TP LINK
4
TP LINK
5
TP LINK
6
TP LINK
TP LINK
TP LINK
9
10
TP LINK
FBR LINK
FBR LINK
FBR LINK
FBR LINK
7
8
TP LINK
11
TP LINK
12
FBR LINK
FBR LINK
FBR LINK
FBR LINK
FBR LINK
FBR LINK
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
CABLE SPECIFICATIONS
The physical characteristics of the media cable must meet or exceed IEEE 802.3 specifications,
1998 Edition.

Fiber Cable

MULTIMODE
Fiber Optic Cable Recommended:
Optional:
Bit error rate:
E-TX-FX-xx00, E-TEL-1200
Fiber-optic Transmitter Power:
Fiber-optic Receiver Sensitivity:
Link Budget
Typical Maximum Cable Distance:*
E-TX-FX-xx00(SC), E-TEL-1200(SC)
Fiber-optic Transmitter Power:
Fiber-optic Receiver Sensitivity:
Link Budget
Typical Maximum Cable Distance:*
E-TX-FX-xx00(MT), E-TEL-1200(MT)
Fiber-optic Transmitter Power:
Fiber-optic Receiver Sensitivity:
Link Budget
Typical Maximum Cable Distance:*
SINGLEMODE
Fiber Optic Cable Recommended:
Bit error rate:
E-TX-FX-xx00(SM), E-TEL-1200(SM)
Fiber-optic Transmitter Power:
Fiber-optic Receiver Sensitivity:
Link Budget
Typical Maximum Cable Distance:*
E-TX-FX-xx00(LH)**, E-TEL-1200(LH)** 1300 nM
Fiber-optic Transmitter Power:
Fiber-optic Receiver Sensitivity:
Link Budget
Typical Maximum Cable Distance:*
*Actual distance dependent upon physical characteristics of network installation.
**Requires a minimum loss of 5 dB over cable or damage to receiver may occur.
62.5 / 125 µm multimode fiber
100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber
10
-11
1300 nM
min: -19.0 dBm
max: -14.0 dBm
min: -30.0 dBm
max: -14.0 dBm
11.0 dB
2 kilometers
1300 nM
min: -19.0 dBm
max: -14.0 dBm
min: -30.0 dBm
max: -14.0 dBm
11.0 dB
2 kilometers
1300 nM
min: -19.0 dBm
max: -14.0 dBm
min: -33.5 dBm
max: -14.0 dBm
14.5 dB
2 kilometers
9 µm singlemode fiber
10
-11
1300 nM
min: -15.0 dBm
max: -8.0 dBm
min: -31.0 dBm
max: -8.0 dBm
16.0 dB
20 kilometers
min: -8.0 dBm
max: -2.0 dBm
min: -34.0 dBm
max: -7.0 dBm
26.0 dB
40 kilometers