Transition Networks E-TEL-1200 User Manual

100base-tx/100base-fx multi-port media converter

Advertisement

Quick Links

COMPLIANCE INFORMATION

UL Listed
C-UL Listed (Canada)
CISPR/EN55022 Class A
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference, in which case the user will be
required to correct the interference at the user's own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on
the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables
aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique
édicté par le ministère des Communications du Canada.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes
Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen
werantwortlich ist.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des
interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques
appropriées
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in
damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten
verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur
Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen
einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners.
Copyright Restrictions
© 1999 TRANSITION Networks.
All rights reserved. No part of this work may be reproduced or used in any form or by any means –
graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Printed in the U.S.A.
The rack-mountable E-TX-FX-1200, E-TEL-1200, and E-TX-FX-0600 series
multi-port media converters with
administrator of a large and complex network to extend the distances
between multiple sets of 100BASE-TX and 100BASE-FX devices.
TP LINK
1
FBR LINK
POWER
ACT
ACT
E-TX-FX-1200
connections between Fast Ethernet
connectors) and Fast Ethernet
fiber connectors, selected as a set according to network requirements).
E-TEL-1200
connections between Fast Ethernet
connector) and Fast Ethernet
connectors, selected as a set according to network requirements).
E-TX-FX-0600
connections between Fast Ethernet
connectors) and Fast Ethernet
connectors, selected as a set according to network requirements).
Fiber Cable/Connector Options* by Model:
E-TX-FX-xx00/E-TEL-1200: multimode fiber, ST connectors
E-TX-FX-xx00(SC)/E-TEL-1200(SC): multimode fiber, SC connectors
E-TX-FX-xx00(MT)/E-TEL-1200(MT): multimode fiber, MT-RJ connectors
E-TX-FX-xx00(SM)/E-TEL-1200(SM): singlemode fiber, SC connectors
E-TX-FX-xx00(LH)/E-TEL-1200(LH): singlemode fiber, SC connectors
*See page 9 for detailed specifications.
*The LinkAlert™ feature allows each
media converter port to pass link faults
between connected 100BASE-TX and
100BASE-FX devices.
33134.B
100BASE-TX/100BASE-FX
Multi-Port Media Converter
E-TX-FX-1200, E-TEL-1200, E-TX-FX-0600
USER'S GUIDE
LinkAlert™*
4
TP LINK
2
TP LINK
3
TP LINK
TP LINK
5
TP LINK
6
TP LINK
7
FBR LINK
FBR LINK
FBR LINK
FBR LINK
FBR LINK
FBR LINK
ACT
ACT
ACT
ACT
ACT
Provides twelve (12) independent media converter
(shown)
over twisted-pair copper (twelve RJ-45
over singlemode or multimode fiber (twelve
Provides twelve (12) independent media converter
(not shown)
over twisted-pair copper (one 50-pin Telco
over singlemode or multimode fiber (twelve fiber
Provides six (6) independent media converter
(not shown)
over twisted-pair copper (six RJ-45
over singlemode or multimode fiber (six fiber
E-TX-FX-xx00 in the Network . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . .4
Operation . . . . . . . . . . . . . . . . . . . . .6
Fault Isolation and Correction . . . . .8
Cable Specifications . . . . . . . . . . . . .9
Technical Specifications . . . . . . . . .11
Compliance Information . . . . . . . . .12
Minneapolis, MN 55344 USA
allow the network
TP LINK
8
TP LINK
9
TP LINK
10
TP LINK
11
TP LINK
12
FBR LINK
FBR LINK
FBR LINK
FBR LINK
FBR LINK
ACT
ACT
ACT
ACT
ACT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E-TEL-1200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Transition Networks E-TEL-1200

  • Page 1: Compliance Information

    100BASE-TX/100BASE-FX Multi-Port Media Converter E-TX-FX-1200, E-TEL-1200, E-TX-FX-0600 USER’S GUIDE The rack-mountable E-TX-FX-1200, E-TEL-1200, and E-TX-FX-0600 series multi-port media converters with administrator of a large and complex network to extend the distances between multiple sets of 100BASE-TX and 100BASE-FX devices. TP LINK...
  • Page 2: Technical Specifications

    E-TEL1200(SM), E-TEL-1200(LH), E-TEL-1200(MT) Regulation: EMC Directive 89/336/EEC Purpose: To declare that the E-TX-FX-0600, E-TX-FX-1200 or E-TEL-1200 to which this declaration refers is in conformity with the following standards. EMC-CISPR 22: 1985 Class A; EN 55022: 1988 Class A; EN 50082-1:1992;...
  • Page 3: Cable Specifications

    CABLE SPECIFICATIONS (continued) COPPER CABLE Each RJ-45 connector requires 2 pairs of Category 5 rated cable. The 50-pin Telco connector requires 24 pairs of Category 5 rated cable. Either shielded twisted-pair (STP) or unshielded twisted-pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE. CATEGORY 5: Gauge 24 to 22 AWG...
  • Page 4: Installation

    -15.0 dBm Fiber-optic Receiver Sensitivity: min: -31.0 dBm Link Budget 16.0 dB Typical Maximum Cable Distance:* 20 kilometers E-TX-FX-xx00(LH)**, E-TEL-1200(LH)** 1300 nM Fiber-optic Transmitter Power: min: -8.0 dBm Fiber-optic Receiver Sensitivity: min: -34.0 dBm Link Budget 26.0 dB Typical Maximum Cable Distance:* 40 kilometers *Actual distance dependent upon physical characteristics of network installation.
  • Page 5: Fault Isolation And Correction

    FAULT ISOLATION and CORRECTION If the multi-port media converter fails, isolate and correct the fault by determining the answers to the following questions and then taking the indicated action: Is the POWER LED on the multi-port media converter illuminated? • Is the power cord properly installed in the media converter and in the grounded AC outlet? •...
  • Page 6: Operation

    OPERATION Use the status LEDs to monitor multi-port media converter operation in the network. NOTE: Each 100BASE-TX/ 100BASE-FX media converter port is identified by a number located just above the fiber connector(s) for that 100BASE-TX /100BASE-FX port connection. The LEDs that apply to each 100BASE-TX or 100BASE-FX port connector(s) are located, when facing the multi-port media converter, at the left of the connector(s) for that 100BASE-TX or 100BASE-FX port connection.

This manual is also suitable for:

E-tx-fx-1200E-tx-fx-0600

Table of Contents