Main Unit Connector Configuration
LAN (PoE)
IN1
OUT1
RELAY1
12V/2A
GND
RESET
Legend
LAN (PoE according to 802.1af) connector
IN1 terminals for input in passive/ active mode  (−30 V to +30 V
DC)
     OFF = open OR U
IN
     ON = closed contact OR U
OUT1 terminals of active input for 2N
electric lock connection 8 up to 12 V DC depending on power
supply (PoE: 10 V; adaptor: power supply voltage minus 2 V),
max. 600 mA
RELAY1 terminals with accessible 30 V / 1 A  AC/DC NO/NC
contact. Used for connection of non-critical devices only (lights,
e.g.).
External 12 V / 2 A DC supply terminals 
Grounding terminal
RESET / FACTORY RESET button