4.2.3

Hydraulic control circuit with UAV

To use the device two separate hydraulic circuits (three circuits with UAV) are required. Is there only one
(two) hydraulic circuit on your truck, you can split one of the circuits by using an electromagnetic valve
ELMV.
The connectors of the left side (in travelling direction) are for the hydraulic circuit "Setting-up" and
"Laying down". The connectors of the right side (in travelling direction) are for the hydraulic circuit
"Open" and "Close".
To avoid malfunction of the device check all the hydraulic connections before starting to work.
4.2.4

Warning device

It is in the responsibility of the operating company to install at the plant/carrier/lifting device a visual or
acoustic warning device for pressure loss.