Introduction; Technical Data - Fichtelbahn ReadyServoTurn Manual

Table of Contents

Advertisement

FichtelBahn

02. Introduction

This manual explains the basics step by step for using this module. Careful reading and
taking note of tips will reduce potential errors and therefore the amount of work to
solve failures.
Designated Use
The normal use of the ReadyServoTurn is for model making especially digital model
railways according to this manual. Any improper use will leas to loss of warranty.
Package Contents
- ReadyServoTurn module with or without housing
- Connection terminal for supplying power
- 4x 3-pole terminal for outputs
- 2x jumper (2,54 mm/1 in grid) for bus termination
- Manual
Required Materials
- Switching power supply with 12V-18V, DC min. 2A current
- RJ45 patch cable for connection to BiDiBus

03. Technical Data

Supply voltage
Power consumption (quiescent current)
Servo output
Number of relay outputs
Switching times
Inputs
Protection per output (servo)
Interfaces
Protection class
Ambient temperature (operation)
Ambient temperature (storage)
Permissible relative humidity
Dimensions casing
Weight
Manual ReadyServoTurn
Manual Version 1.0
12V - 18V direct current (DC)
10mA (0,15W)
4x servos with 0.5A continuous operation per output
4x changeover / switching current 2A
20ms to continuous operation
4x inputs with ground reference
Short-circuit proof with switch-off and error message
BiDiBus (RJ45)
IP 00
0 ... +60 °C / 32 ... 140 °F
-10 ... + 80 °C / 14 ... 176 °F
max. 85 %
100mm x 90mm x 34mm / 3.94 in x 3.54 in x 1.34 in
85 g / 3 oz
Page 4
R
eady
Line
(4x 3-pole output terminal)
© 2022 FichtelBahn®
Technical changes and errors reserved
(peak = 1A)