Led Indication - Fichtelbahn ReadyServoTurn Manual

Table of Contents

Advertisement

FichtelBahn

07. LED indication

07.1 Operating Modes
1
fast flicker
Double flashing
2
OFF
continuous lighting
fast flashing
Double flashing
3
continuous lighting
4
flashing
5
continuous lighting
07.2 Error states at module start up
10x fast flashes (1, 2, 3)
No bootloader found / no firmware update possible (contact the FichtelBahn-Support)
Continuous Flashing (1, 2, 3)
EEPROM faulty (conduct a firmware update, see "09. Firmware Update" on page 33)
Continuous Flashing (1, 2)
No BiDiB-Unique-ID found (contact the FichtelBahn-Support)
Manual ReadyServoTurn
Manual Version 1.0
Power-ON LED
ReadyServoTurn is operating
Registration at the bus was rejected
BiDiB-Identify LED
No connection to the BiDiBus
Connected to the BiDiBus
Identify - function active
Registration at the bus was rejected
Error LED
Short circuit or overload on one of the 4 servo ports. The relevant servo port
has been switched off.
Activity LED
There is a movement of one of the 4 servos.
Message LED
Module is in update mode
Power-ON LED, BiDiB-Identify LED, Message LED
Power-ON LED, BiDiB-Identify LED, Message LED
Power-ON LED, BiDiB-Identify LED
Page 31
2
TERM
TAST
ID
DCC BiDiB
R
eady
Line
ReadyServoTurn
4-fach BiDiB-Servodecoder
with 4x Relais and 4x Input
Servo 0
Servo 1
-
+
-
+
D
D
1
1
3
3
Data
GND
Data
GND
REL 0
REL 1
INPUT
0
0
2
2
NO
NC
NO
NC
Data
GND
Data
GND
SERV 0
SERV 1
IN1
IN3
IN0
IN2
REL 0
REL 1
5
4
3
R
eady
Line
1
Power
12V - 18V
+
-
DC
FichtelBahn
Made in Germany
Servo 2
Servo 3
-
+
-
+
D
D
REL 2
REL 3
NO
NC
NO
NC
SERV 2
SERV 3
REL 2
REL 3
© 2022 FichtelBahn®