FichtelBahn
Which servo is suitable - digital or analogue?
One major difference is that a digital servo can move to its position faster and hold the
position more accurately. An analogue servo uses an ohmic potentiometer that loses
its repetition accuracy with temperature chages (tolerance).
Both types of servo can be connected to the ReadyServoTurn.
In the case of an effect, the advantage of the digital servo might make a difference. For
a turnout or other movements with a mechanical positioning spring and strain relief,
the tolerance is unimportant. Here a large travel distance should be chosen and servos
with metal gears should be used. In the FichtelBahn-Shop you will find a reliable and
inexpensive solution with the article no. 410100
04.3.1 Servo protection mechanisms
The ReadyServoTurn is designed for operational safety
with monitoring functions.
Each servo output has overcurrent and short-circuit
detection, which switches off the affected servo output
in the event of a fault. The remaining servo outputs can
still be used.
The error status (shut-off of a servo output) is signalled
by a static red error LED on the module.
If a new servo control command is issued for the defective
output, the control programme receives a message via the ac-
cessory feedback that the servo output could not be switched
and therefore the route is not locked.
The shut-off and error message can only be reset with a
power reset of the ReadyServoTurn.
Please notice:
The overcurrent and short-circuit detection is designed for a continuous load of
500mA / peak = 1A for each servo port.
Manual ReadyServoTurn
Manual Version 1.0
Page 9
R
eady
Line
TERM
TAST
DCC BiDiB
ID
ReadyServoTurn
4-fach BiDiB-Servodecoder
with 4x Relais and 4x Input
1
1
3
3
Data
GND
Data
GND
INPUT
0
0
2
2
Data
GND
Data
GND
IN1
IN3
IN0
IN2
© 2022 FichtelBahn®
Technical changes and errors reserved
R
ead
Line
Servo 0
Servo 1
-
+
-
+
D
D
REL 0
REL 1
NO
NC
NO
NC
SERV 0
SERV 1
REL 0
REL 1
Servo 0 b
Belegung
GND 5

Advertisement

Table of Contents
loading

Table of Contents