Web Page Item
Slow Blink
Fast Blink
Color
Brightness
Red
Green
Blue
Call Disconnection
Terminate Call After Delay
Audio Codec Selection
Codec
RTP Settings
RTP Port (even)
Asymmetric RTP
Jitter Buffer
RTP Encryption (SRTP)
Operations Guide
Table 2-9. SIP Page Parameters (continued)
Description
Strobe will blink ON at the specified brightness for one second then OFF for one
second during the duration of the event.
Strobe will blink ON at the specified brightness then OFF five times per second during
the duration of the event.
Select desired color (only one may be chosen).
How bright the strobe will blink when the Nightringer is ringing. This is the maximum
brightness for "fade" type scenes.
The red LED value for Nightringer.
The green LED value for Nightringer.
The blue LED value for Nightringer.
Use this button to preview the strobe flashing behavior for the Nightringer Strobe
Settings.
Automatically terminate an active call after a given delay in seconds. A value of 0 will
disable this function. Enter up to 8 digits.
Select desired codec (only one may be chosen).
Specify the port number used for the RTP stream after establishing a SIP call. This
port number must be an even number and defaults to 10500. The supported range is
0-65536. Enter up to 5 digits.
Specify if the remote endpoint will send and receive RTP packets on different ports. If
set to false, the device will track the address/port that is sending RTP packets during a
SIP call. If the address/port changes mid-stream, the device will disregard the SDP
and send all further RTP packets to this new address.
If set to true, this device will ignore the sending address/port and send RTP as
specified in the SDP. Warning! Enabling asymmetric RTP can cause the RTP stream
to be lost.
Most installations should not enable asymmetric RTP.
Specify the size of the jitter buffer (in milliseconds) used for SIP calls. Valid values are
50-1000.
When enabled, a SIP call's audio streams are encrypted using SRTP.
Click the Save button to save your configuration settings.
Click on the Reboot button to reboot the system.
Click on the Toggle Help button to see a short description of some of the web page
items. First click on the Toggle Help button, and you will see a question mark (
appear next to some of the web page items. Move the mouse pointer to hover over a
question mark to see a short description of a specific web page item.