G1 Alarm And Control Unit (Automatic Distress Signal Unit, Adsu) (Version With Integrated Electronics Only) - MSA G1 Operating Manual

Hide thumbs Also See for G1:
Table of Contents

Advertisement

2.7
G1 Alarm and Control Unit (Automatic Distress Signal Unit, ADSU) (Version with Integrated
Electronics Only)
The alarm and control device is a combination of the control module located on the chest and the
power module integrated into the backplate of the SCBA. The integrated motion sensor detects
movements and goes into full alarm when the user remains motionless for 30 seconds. The
G1 alarm and control unit uses acoustic and visual alarm indications.
G1 Control Module (Version with Integrated Electronics Only)
1
2
Fig. 7
Control module
1
Analog gauge
2
Color display
3
Power/pressure inlet
The G1 control module is the user's interface with the SCBA and ADSU device.
The control module is assembled to the high pressure air source and to the power module by a
pneumatics and electronic hose assembly. The unit combines an analog gauge and graphical
display to provide current status information of the SCBA:
numeric cylinder pressure
battery status
alarms
power module status
remaining service time
Telemetry radio link and evacuation status
The control module automatically lights up the analog gauge and turns the display on when the
user lifts the unit up from the chest.
Furthermore the control module serves the user with a manual alarm button that activates the full
acoustic and visual alarms of the device.
4
5
3
4
5
G1 Integrated SCBA System
Manual alarm
Reset button
Description
GB
16