Special conditions for safe use:
Properly donning and doffing of the self-contained breathing apparatus shall be done only in
non-hazardous areas.
Before entering the hazardous area, the complete self contained breathing apparatus elec-
tronics type G1 has to be checked for mechanical damages including the conductive ink layers
of the housings.
The disconnection of the alkaline battery pack and the changing of the batteries is only allowed
in non hazardous area.
Replace only batteries of the same type
-The maximum RF radiation power of the antenna used for activation of the RFID Tag type
LOGI TAGTM 161 HF in hazardous areas shall not exceeded 2W for Group IIC.
The ambient temperature range is - 30 °C ≤ Ta ≤ + 60 °C .
Quality Assurance Notification: 0080
Year of Manufacture:
Serial No.:

18.4 Australia

The LRR frequency for Australia is 915 - 928 MHz.
see Label
see Label
G1 Integrated SCBA System
Certification
GB
82