16

Safekeeping and Storage

16.1 Storage

WARNING!
Prior to storage of the SCBA at temperatures below -18°C, verify that the power module is
equipped with full charge batteries. Verify that the control module displays a full charge battery
status icon and that the HUD does not display low battery status indicators.
DO NOT drop the cylinder or bump the valve knob. An unsecured cylinder can become an
airborne projectile under its own pressure if the valve is opened even slightly.
Misuse can result in serious injury or death.
Do not store the SCBA or spare cylinders within or near an area where the SCBA can or might
be exposed to any substances that will or might attack any part of the SCBA, causing the SCBA
to not perform as designed and approved.
Prior to storing the SCBA in a jumpseat, ensure there is no interference between the SCBA
and the seat. Ensure the SCBA and cylinder can be removed easily without damaging the
components.
Do not store the SCBA for extended periods with the batteries installed in the electronic
components if the SCBA is not intended for service. If the SCBA is in service, ensure that the
batteries in the electronic components have an adequate charge.
Do not store the SCBA with an empty or partially filled cylinder. Always install a fully-charged
cylinder so that the SCBA is ready for use.
Complete Inspection and Cleaning and Disinfecting Procedures outlined in this manual.
Ensure the entire SCBA is clean and dry.
Ensure the full face mask head harness adjustment straps are fully extended. Place the
complete SCBA in the storage case or suitable storage location so it can be easily reached for
emergency use.
For prolonged storage of the SCBA, remove the batteries from all electronic components and
housings to prevent battery corrosion. Store the units in a cool, dry place.

16.2 Full Face Mask

WARNING!
In order to avoid damage to or the deformation of the masks keep no additional loose objects in
the mask container.
For the safekeeping of the full face mask, a full face mask pouch or container should be used.
MSA rubber products are protected by an anti-aging agent that can become visible as a light
coating. This coating is harmless and can be removed during cleaning.
To ensure a long life of rubber components, follow ISO 2230 by storing them in a cool, dry place
protected from ultraviolet radiation.