FISCHER PRO-LINE DE90 Operating Manual page 63

Differential pressure transmitter
Table of Contents

Advertisement

FISCHER Mess- und Regeltechnik GmbH
5.5.1.5.1 Colour change C1 type: red/green
For example:
5.5.1.5.2 Colour-change C1 type: red/yellow/green
BA_EN_DE90
The following switching thresholds are relevant for this colour change:
RED
MS
S1
Fig. 83: Colour change red/green
Meas.range C1 start
MS
Col.ch. C1 red–grn
S1
Col.ch. C1 grn–red
S2
Meas.range C1 end
ME
Input of the threshold red/green
Directory: \Parametrierung\Kanal 1\Farbwechsel K1\Farbw. C1 red-green
Level: 4
Col.ch. C1 red–grn
1
Fig. 84: Colour change C1 red-green
The other switch thresholds are entered in the same way.
The following switching thresholds are relevant for this colour change:
RED
MS
S1
Fig. 85: Colour change red/yellow/green
Meas.range C1 start
MS
Col.ch. C1 red-ylw
S1
Col.ch. C1 ylw-grn
S2
Col.ch. C1 grn/ylw
S3
Col.ch. C1 ylw/red
S4
Meass.range C1 end
ME
Basic measuring range
GREEN
See menu
See menu
25.000
Edit
OK Cancel
2 3
4
Basic measuring range
YELLOW
GREEN
S2
See menu
See menu
RED
S2
Measurement C1
Measurement C1
U
Pa
YELLOW
RED
S3
S4
Measurement C1
Measurement C1
Operation | 5
ME
: [} 47]
: [} 47]
ME
: [} 47]
: [} 47]
63

Advertisement

Table of Contents
loading

Table of Contents