De45 series digital differential pressure switch/transmitter
Hide thumbs Also See for DE45 series:

Advertisement

d e v e l o p i n g
s o l u t i o n s
Data Sheet and Operating Manual
DE45
Digital differential pressure switch / transmitter
DE45##00###K#6L#S####
Dust explosion protection Zone 22 dry dusts
Table of contents
1
Safety Instructions
2
Application Purpose
3
Description of the Product and Functional Description
4
Installation and Assembly
5
Commissioning
6
Maintenance
7
Transport
8
Service
9
Accessories
10 Disposal
11 Technical data
12 Dimensional drawings
13 Order Codes
14 Manufacturer's Declarations and Certificates
  II 3D
Ex tc IIIB T125° IP65
-10°C ≤ Tamb ≤ 60°C
1
Safety Instructions
1.1
General
This operating manual contains instruc-
tions fundamental to the installation,
operation and maintenance of the de-
vice that must be observed uncondi-
tionally. It must be read by the assembler, operator
and the specialized personnel in charge of the de-
vice before it is installed and put into operation.
This operating manual is part of the product and
must be kept close by where it is easily accessible
to the responsible specialized personnel.
The subsequent sections, in particular the instruc-
tions on assembly, commissioning and mainte-
nance, contain important safety instructions, the
non-observance of which can endanger persons,
animals, the environment and physical objects.
1.2
Personnel Qualification
The device may only be installed and commis-
sioned by specialized personnel familiar with the in-
stallation, commissioning and operation of this
product.
Specialized personnel are persons who can assess
the work they have been assigned and recognize
potential dangers by virtue of their specialized train-
ing, their skills and experience and their knowledge
of the relevant standards.
For explosion-proof models the specialized person-
nel must have received special training or instruc-
tion or be authorized to work with explosion-proof
instruments in explosion hazard areas.
1.3
Risks due to Non-Observance of Safe-
ty Instructions
Non-observance of these safety instructions, the in-
tended use of the device or the limit values given in
the technical specifications can be hazardous or
cause harm to persons, the environment or the sys-
tem itself.
The manufacturer will not be liable for damage
claims if this should happen.
1.4
Safety Instructions for the Operating
Company and the Operator
The safety instructions on correct operation of the
device must be observed. The operating company
must make them available to the installation,
maintenance, inspection and operating personnel.
Dangers arising from electrical components, energy
discharged by the medium, escaping
medium and incorrect installation of the
device must be eliminated. For more in-

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DE45 series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FISCHER DE45 series

  • Page 1 d e v e l o p i n g s o l u t i o n s Data Sheet and Operating Manual DE45 Digital differential pressure switch / transmitter DE45##00###K#6L#S#### Dust explosion protection Zone 22 dry dusts Table of contents Safety Instructions Application Purpose Description of the Product and Functional Description...
  • Page 2: Application Purpose

    This also applies to replacement parts. Any modifications / al- Description of the Product and Func- terations required must be carried out by Fischer tional Description Mess- und Regeltechnik GmbH only. Function Diagram...
  • Page 3: Installation And Assembly

    lower pressure. This movement of the diaphragm Electrical Connection, Explosion Pro- induces a change of resistance, which is evaluated tection Instructions by the device's electronics and transformed into signals on the display, switch contacts and an out- By authorized and qualified specialized person- put signal.
  • Page 4: Commissioning

    Supply voltage / signal output: available. For example, all characteristic curve func- tions are faded out in the menu if the device does The nominal supply voltage and the permissible not have a signal output. range can be found in the technical data. All the device settings can be made easily on the The admissible load / resistance for the signal out- PC using the PC adapter.
  • Page 5 In many cases the unsteady readings are not a The value defined via the parameter is issued if problem in normal mode, but can be a problem in the device detects an internal error and can no idle mode, i.e. if one expects a zero (differential) longer work correctly.
  • Page 6 to the main menu at this point, i.e. if you change to tact, if the value = 2, the switch output works as a again via the key û. If the table is NC contact. the parameter not structured correctly, an error message will 5.2.9 Password...
  • Page 7 Parameter overview Start of measuring range Set the measuring value that results in After switching on the device, it will briefly indicate a minimum output signal (depending the software version number and before entering on the version, this is 0 V, 0 mA or û...
  • Page 8: Maintenance

    Maintenance Service The instrument is maintenance-free. All damaged or faulty devices must be sent directly to our repair department. Please coordinate all We recommend checking the instrument at regular shipments with our sales department. intervals to ensure reliable operation and a long service life.
  • Page 9: Technical Data

    11 Technical data + ranges (0 … ) ± ranges mbar 60 100 160 250 2.5 Measuring Range 0.4 0.6 1.0 1.6 2.5 4.0 6.0 10.0 16.0 25.0 0.25 0.4 0.6 1.0 1.6 2.5 4.0 6.0 Static operating max. mbar 1500 pressure Bursting pressure...
  • Page 10: Dimensional Drawings

    12 Dimensional drawings Wall mounting plate (optional) Rear view Without wall mounting plate Earth connection Boreholes for tapping screws diam. 3.5 mm Hose screw connection for 6 or 8 mm hose Connector 2 Connector 1 12.1 Panel mounting set Wall thickness 3-5...
  • Page 11: Order Codes

    13 Order Codes Digital differential pressure switch / transmitter, with 3 ½-digit LED display Type DE45 S#### Measuring Range 0 … 4 mbar ..................> 5 0 … 6 mbar ..................> 5 0 … 10 mbar ..................> 5 0 …...
  • Page 12: Manufacturer's Declarations And Certificates

    Technische Änderungen vorbehalten • Subject to change without notice • Changements techniques sous réserve Fischer Mess- und Regeltechnik GmbH • Bielefelder Str. 37a • D-32107 Bad Salzuflen • Tel. +49 5222 9740 • Fax +49 5222 7170 • eMail: info@fischermesstechnik.de • www.fischermesstechnik.de...

Table of Contents