Control Techniques Commander SK Getting Started Manual page 32

Ac variable speed drive for 3 phase induction motors from 0.25kw to 4kw, 0.33hp to 5hp
Hide thumbs Also See for Commander SK:
Table of Contents

Advertisement

Safety
Rating
Mechanical
Information
Data
Installation
Figure 6-12 Brake function diagram
Current
magnitude
Brake release
current threshold
46
47
Brake applied
current threshold
Output
frequency
Brake release
frequency
48
Brake apply
frequency
49
Reference
on
Figure 6-13 Brake sequence
Output frequency
Output current
Brake release
Ramp hold
Pr 52 to Pr 54 appear when a fieldbus option is fitted to the drive.
No
Function
52
Fieldbus node address
No
Function
53
Fieldbus baud rate
No
Function
54
Fieldbus diagnostics
See the appropriate fieldbus option module manual for further information.
32
Electrical
Keypad and
Parameters
Installation
Display
+
Drive
active
_
+
Latch
In
Out
_
Reset
+
_
Pr
48:
Brake
release frequency
Pr
46
: Brake release
current threshold
Pr
50
:
Pre brake
release delay
www.controltechniques.com
Quick Start
Diagnostics Options
Commissioning
Pre-brake
release
delay
50
51
Post brake
release
delay
Pr
51
:
Post brake
release delay
Range
0 to 255
Range
0 to 8
Range
-128 to +127
Commander SK Getting Started Guide
Parameter
UL Listing
List
Information
Brake
Ramp
disabled
hold
Brake
release
programmable
12
Brake
controller
enable
Pr
49
:
Brake applied
frequency
Defaults
Type
0
RW
Defaults
Type
0
RW
Defaults
Type
0
RW
Issue Number: 1
T5
T6
B3