Minelab F3 Service Manual page 41

Metal mine detector
Hide thumbs Also See for F3:
Table of Contents

Advertisement

3
32-31016-999
4
32-31000-922
5
32-31006-922
6
4005-0039
7
8008-0052
3011-0293
3011-0294
8
2004-0009
a.
To Connect the UXO Coil to an F3:
First remove the 20cm coil as described in section
Attach the friction blocks (6) to the lower camlock body at the end of the lower
shaft of the F3 detector and then fit the adapter coil yoke (10) on to the friction
blocks. As shown in figure 37.
Connect the coil cable to the coil cable pull through tool or use a piece of string
to thread the coil cable through the shafts of the F3 detector.
Prior to threading the cable through the shafts, ensure the cable has 52 turns
in the coil cable curly section.
Feed the coil cable into the detector shafts as shown in figure 38.
Attach the coil adapter to the top of the UXO coil. Thread the long nylon bolts
through the coil adapter and coil then attach the nylon nuts to the bolts.
Bolt Nylon 5/16-18 X 4.0 Hex Hd
Nut Nylon 5/16-18 Knurled
Screw Nylon 5/16-18 X1.5 Knurled
Friction Block Coil
Adapter Coil Yoke UXO
Guide Arm
Kit GA-10 hinge/strap
Skid Plate F3 UXO
Figure 37: Coil Adapter.
Page 41
F3 Service Manual
4.4.a. To remove a coil.

Advertisement

Table of Contents
loading