F3 Service Manual
Coil Connector
Figure 15: Connecting Electronics Pack to shaft and connect coil.
Slide the electronics pack along the upper shaft into place, ensuring the wiring
loom cable lays in the cut out at the top of the electronics pack rear cover.
Refit the two screws (Part 7) securing the electronics pack to the upper shaft.
Shown in Figure 15.
Check the condition of the O-ring (Part 8) and apply a small amount of silicone
grease as required.
Ensure the O-ring (Part 8) is positioned correctly in the groove under the cover
bulkhead in the electronics pack rear panel.
Ensure that the keyway on the wiring loom plug is towards the bottom of the
electronics pack then plug the main wiring loom into the connector in the
electronics pack. Refer to Figure 16.
O-ring seal
Align connector key way
Figure 16: Connecting Wiring Loom into the Electronics Pack.