Enter to mode [PERF] you can set the performance characteristics of the fixture:
- [LIVE] mode is the default mode which balances the requirements of output and noise.
- [STDO] mode maintains extremely low noise at all times and operates at a moderated power level.
- [POWR] mode operates at high power for long periods of time without making considerations for
noise levels.
SLCK
• In this function [SLCK] you can enable or disable the password to access the settings menu.
• Select [ON] or [OFF].
When the fixture is set as pass [ON], after 30 seconds or turn on the fixture next time, the fixture will
need an access password to enter in settings menu.
NOTE - The factory access password is UP + DOWN + UP + DOWN. Press ENTER to confirm the access.
DERR
Enter to [DERR] to control in case of DMX signal errors.
- [SAVE] saves the latest data DMX on error DMX signal.
- [BLACK] allows you to activate the mode on error DMX blackout.
REST
In order to reset custom modes to default values select [REST].
NOTE - The factory access password is UP + DOWN + UP + DOWN. Press ENTER to confirm the access.
MCON
The function [MCON] allows the user to select whether the fixture will send DMX data to other fixture
during stand-alone operation.
The [MAST] setting allows data to be sent to other fixtures.
The [SELF] setting is default and will not send DMX data to other fixtures.

3.6 MASTER/SLAVE MODE

This mode will allow you to link up the units together without a controller. Choose a unit to function as the
Master. The unit must be the first unit in line; other units will work as slave with the same effect.
• Press the button MENU so many times until the display shows [RUN] and press the button ENTER.
• Press UP/DOWN to set the unit as slave [SLAV].
• Use standard DMX cables to daisy chain your units together via the DMX connector on the rear of the
units. For longer cable runs we suggest a terminator at the last fixture (see page 12).

3.7 LINKING

Several units may be interconnected in order to control all further slave units to the same effect of the
master unit.
1. Connect the DMX OUT of the master unit via 3/5-poles XLR cable to the DMX IN of the first slave unit.
2. Connect the DMX OUT of the first slave unit to the DMX IN of the second slave unit, etc. until all units
are connected in a chain.
EVO90F
11