gefran GFW 400A Installation And Operation Manual page 37

Modular power controller
Table of Contents

Advertisement

Figure 42
GFW connection example for 3 independent loads in open delta, 3-phase line without neutral
(*)IMPORTANT:
Take care
to connect
terminals 1/L1
and 3/L1 to the
same phase
(**)Only required
with Vload
measurement
input option.
GFW Master - Dip-Switches Configuration
Dip 1
Dip 2
Dip 3
OFF
ON
OFF
Figure 43
Example of GFW3-PH wiring for 3 indipendent single-phase loads
It is possible to connect three single-phase loads also to three different line voltages, between line to line or line to neutral.
It is possible to manage by Fieldbus different power values for each one of the three loads.
(*)IMPORTANT:
Take care
to connect
terminals 1/L1
and 3/L1 to the
same phase
(**)Only required
with Vload
measurement
input option.
80999D_MHW_GFW 400-600A_07-2020_ENG
Dip 4
Dip 5
OFF
OFF
V line voltage
P power of each single-phase load
Id load current if resistive load cosφ=1
FIRING MODE ZC, BF, HSC, PA
HB DIAGNOSTIC
Partial and total load failure pof each single leg
AVAILABLE
Fast Fuse Needed only for controller with option Fuse = 0
GG Fast Fuse See Fuse section
GFW Master - Dip-Switches Configuration
Dip 1
Dip 2
Dip 3
Dip 4
OFF
OFF
OFF
OFF
V line voltage
P power of each single-phase load
Id load current if resistive load cosφ=1
FIRING MODE ZC, BF, HSC, PA
HB DIAGNOSTIC
Partial and total load failure pof each single leg
AVAILABLE
Fast Fuse Needed only for controller with option Fuse = 0
GG Fast Fuse See Fuse section
Dip 5
OFF
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gfw 500aGfw 600a