3.21 Only One Test
Subtest 03
Subtest 04
NOTE: When executing this subtest, USB test module and USB cable must be connected.
###############################################################
########
###############################################################
*
*
*
*
*
*
*
***************************************************************
.... Press test number[0-2, 9] ?
PORTEGE M400 Maintenance Manual (960-541)
Get user manuals:
See SafeManuals.com
Kill Switch
This subtest checks if the Wireless communication switch works properly.
If the test is started with the switch ON, the following message appears in the
display.
Kill switch is set to a start position (OFF)
Slide the switch to OFF position. Then, the following message appears in the
display.
KILL SWITCH ON !!
Slide the switch to ON position. Then, the following message appears in the
display.
KILL SWITCH OFF !!
After Sliding the switch to OFF position, the screen returns to the Only One
Test menu automatically.
USB
This subtest checks if USB ports work properly.
The following menu appears in the display.
USB Port Select (XXXXXXXXX)
0
Port 0 (Back)
1
Port 1 (Left side back)
2
Port 2 (Left side front)
9
EXIT to Only One Menu
Connect the USB test module and USB cable to the computer.
Input the test port number and press Enter.
OK message appears in the display if the test ends without an error.