FAAC J355HA M50 Translation Of The Original Instructions

FAAC J355HA M50 Translation Of The Original Instructions

Hide thumbs Also See for J355HA M50:

Advertisement

Quick Links

J355HA M50
Translation of the original instructions

Advertisement

Table of Contents
loading

Summary of Contents for FAAC J355HA M50

  • Page 1 J355HA M50 Translation of the original instructions...
  • Page 2 Nessuna parte di questo manuale può essere riprodotta, archiviata, distribuita a terzi né altrimenti copiata, in qualsiasi formato e con qualsiasi mezzo, sia esso elettronico, meccanico o tramite fotocopia, senza il preventivo consenso scritto di FAAC S.p.A. Tutti i nomi e i marchi citati sono di proprietà dei rispettivi fabbricanti.
  • Page 3: Table Of Contents

    1. BOLLARD J355HA M50 ........
  • Page 4: Bollard J355Ha M50

    1. BOLLARD J355HA M50   Please read this manual carefully. It accompanies the product, providing important information regarding safety, installation and use. 1.1 GENERAL INSTRUCTIONS These instructions apply to the model J355HA M50 This model refers to automatic hydraulic counter-terrorism traffic bollards. The cylinder is moved by a hydraulic unit inside the structure.
  • Page 5: Dimensions

     1 Table A - Technical specifications (1) Check the oil level using the dipstick positioned under the filler cap (1-7) with the piston rod fully inside and the EFO MODEL J355HA M50 system under pressure. Power supply 230 V~ (+6% -10%) 50 (60) Hz (2) The starting capacitor (70μF - 400v) is pre-wired inside the junc-...
  • Page 6: Installation

    A flexible hose with a diameter of Ø100 mm should be fitted for drainage. Dig the hole to a depth of approximately 1.85 m IMPACT DIRECTION UNPROTECTED AREA PROTECTED AREA 3100 Excavation Ground Dimensions in mm 3 J355HA M50 532141 - Rev. A...
  • Page 7: Construction Of The Foundation Cage

    2.2 CONSTRUCTION OF THE FOUNDATION CAGE Build the foundation cage (not supplied by FAAC) as shown in 4 using the Ø 12mm and Ø 20 mm iron rods - CLASS B450C 4 J355HA M50 532141 - Rev. A...
  • Page 8: Fixing The Pit In Place

    Lay the piping necessary for connecting the bollard, the control board and any additional devices and finish the road surface with the same type of concrete. N.B.: All piping must be laid in compliance with the applicable rules in force. J355HA M50 532141 - Rev. A...
  • Page 9 The steel reinforcement complies with the B450C class (ASTM A615 - Concrete with aggregate 10-30 pursuant to UNI EN 12620 Grade 60). - The bollard must only be installed once the concrete has cured for at least 7 days. J355HA M50 532141 - Rev. A...
  • Page 10: Electrical Wiring

    8-2 then connect the corrugated conduits to the supports on the bollard frame, as indicated in 8-3. Complete the electrical connections in the terminal box at the side of the bollard as shown in 14. 8 J355HA M50 532141 - Rev. A...
  • Page 11: Insertion Into The Pit

    2.6 FIXING THE TOP COVER After fixing the bollard in place, complete the installation by position- ing and fixing the top cover with the six M8x40 steel screws provided.  1 0 12 J355HA M50 532141 - Rev. A...
  • Page 12: Efo (Emergency Fast Operation - Optional)

    OPTIONAL) The standard sequence of routine maintenance is as follows: The bollard J355HA M50 can be equipped with an EFO (Emergency Fast Operation) emergency activation system, which can be activated 1. Clean the pit by sucking out any deposited material at any time to raise the cylinder immediately.
  • Page 13: Electronic Device Je275

    LOOP 1 EFO N.O. connection (activtes also in case of black out) EFO N.C. connection (voluntary activation only) EMERGENCY EMERGENCY 230 V~ 230 V~ Bollard side Board side Bollard side Board side 14 J355HA M50 532141 - Rev. A...
  • Page 14: Board Programming

    After connecting and switching on the power to the control board as per the previous chapter, select the work pre-setting for the bollard J355HA M50 by performing the following operation: 1. Access level 1 programming by holding down the F button on the control board (15).
  • Page 15: Connecting Several Bollards (Master/Slave)

    SLAVE configuration. Follow the following guidelines for proper wiring and operation of the devices. JE275 MASTER JE275 SLAVE  10 s 10 11 12 13 16 17 16 17 JE275 JE275 JE275 MASTER SLAVE SLAVE 16 J355HA M50 532141 - Rev. A...
  • Page 16 FAAC S.p.A. Soc. Unipersonale Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALY Tel. +39 051 61724 - Fax +39 051 758518 www.faac.it - www.faacgroup.com J355HA M50 532141 - Rev. A...

Table of Contents