Zone Heaters; Defining Non-Variable Zone Heaters; Defining Variable Zone Heaters - Munters Trio User Manual

Poultry controller
Hide thumbs Also See for Trio:
Table of Contents

Advertisement

9.2 Zone Heaters

Define relays and/or analogue output ports as heaters in Devices and Sensors.
Define at least one heater as a Zone Heater in Devices and Sensors.

Defining Non-Variable Zone Heaters

Defining Variable Zone Heaters

9.2.1 D
N
EFINING
ON
1. Go to Climate > Zone Heaters.
2. Click
.
3. Define:
o On Temp Diff: This is a differential. When the temperature reaches the target temperature
minus this amount, heating begins.
o Off Temp Diff. This is a differential. When the temperature reaches the target temperature
minus this amount, heating stops.
9.2.2 D
V
EFINING
ARIABLE
1. Go to Climate > Zone Heaters.
2. Click
.
3. Define:
o On Temp Diff: This is a differential. When the temperature reaches the target temperature
minus this amount, heating begins.
-V
Z
H
ARIABLE
ONE
EATERS
Z
H
ONE
EATERS
© Munters AB, 2020
60