12.2 Zone Heaters

Define at least one heater as a Zone Heater. Refer to the Installation Manual.

Defining Non-Variable Zone Heaters

Defining Variable Zone Heaters

12.2.1 D
N
EFINING
ON
1. Go to Climate > Zone Heaters.
2. Click
.
3. Define:
o On Temp Diff: This is a differential. When the temperature reaches the target temperature
minus this amount, heating begins.
o Off Temp Diff. This is a differential. When the temperature reaches the target temperature
minus this amount, heating stops.
12.2.2 D
V
EFINING
ARIABLE
1. Go to Climate > Zone Heaters.
2. Click
.
3. Define:
o On Temp Diff: This is a differential. When the temperature reaches the target temperature
minus this amount, heating begins.
o Off Temp Diff. This is a differential. When the temperature reaches the target temperature
minus this amount, heating stops.
o Max Heat Temp: Set the temperature under which the heaters work at their maximum
output.
o Min/Max Output: Set the voltage output for minimum and maximum.
-V
Z
H
ARIABLE
ONE
EATERS
Z
H
ONE
EATERS