2. Define the Minimum Heater Output. Range: 0 – 100%
10.2.2
H
C
EAT
To enable running heaters in a cycle:
1. Go to System > Control Strategy > Climate
2. Enable Heater Cycle.
3. Go to Climate > Heating > Settings.
4. Define:
o Total Cycle Time (sec.): Range 5 – 600 seconds. Default 300 seconds
o Minimum Cycle On Time (sec): Range 5 – 600 seconds. Default 60 seconds
o Minimum Cycle Off Time (sec): Range 5 – 600 seconds. Default 30 seconds

10.3 Zone Heaters

A zone is an area in the pig house. Each zone heater can be mapped to specific temperature
sensor(s) and operates according to that sensor's data output. The heat set point in the
temperature curve is the same for all zones. Once a zone's heater is activated, it will work
to maintain the temperature. All zone heaters work independently.
Define relays output ports as heaters. Refer to the Installation Manual.