Safety
Introduction
Installation Precautions
The foam system is intended to be installed by a person or persons with
the basic knowledge of installing similar equipment. Contact Waterous with
questions about installing the foam system.
Disconnecting the Frame Ground
The foam system uses a frame ground to operate. Performing high
voltage or high current operations, while the foam system is connected
to the frame, can damage the electronics in the control box.
NOTICE
High Current
High current from welding
•
or jump start can damage
electronic components.
Disconnect all ground
•
wire connections before
jumping or welding.
Avoid damaging the electronics in the control box. Disconnect
the frame ground before jump starting, welding, plasma cutting
or conducting other high voltage or high current operations to the
apparatus.
Product Overview
Installation
Operation
Modifying the Foam System
The foam system components are designed to operate mounted to
the mounting bracket. Removing the components from the mounting
bracket
(Figure
1,
Figure 2
independently, can damage the components, and will void your
warranty.
NOTICE
Modification
Modifying the equipment
•
can damage components
and void your warranty.
Do not modify the foam
•
system.
Do not modify the foam system or any of its components. Doing so
will void your warranty.
|
35
64
Maintenance
Troubleshooting
and
Figure
3) and installing them