Cleaning The Wye Fitting With Strainer; Inspecting The Hoses And Fittings; Inspect The Mounting Hardware - Waterous AQUIS 1.5 Installation, Operation And Maintenance Instructions

Table of Contents

Advertisement

Safety
Introduction

Cleaning the Wye Fitting with Strainer

Clean the wye fitting every 50 hours of use.
1. Close the shutoff valve at the supply tank.
2. Understand and follow the safety instructions from the foam concentrate
manufacturer.
3. Place a container underneath the strainer to collect the concentrate that
drains from the strainer.
4. Remove the cap at the end of the wye fitting
2
3
1. Wye fitting
5. Remove the strainer from the wye fitting.
6. Flush the debris from the stainer.
7.
Insert the strainer into the wye fitting.
8. Secure the cap to the wye fitting
9. Open the shutoff valve at the supply.
Product Overview
47).
(Figure
2. Strainer
3. Cap
Figure 47
47).
(Figure
Installation
Operation

Inspecting the Hoses and Fittings

Check the hoses and fittings every 50 hours of use.
• Check the hoses for wear, deterioration, and leaks.
• Check the fittings for deterioration and leaks.

Inspect the Mounting Hardware

Inspect the mounting hardware every 500 hours of use.
• Make sure the mounting hardware is free from oxidation.
• Make sure the mounting hardware secures the pump to the apparatus.
Tighten if necessary.
1
|
61
64
Maintenance