Section 5
Host Communications Specifications
GET MULTI-READER/WRITER SETTINGS
You can use this command to check the multi-Reader/Writer settings in a Reader/Writer.
 Command Area
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
 Response Area
ErrCode/Error Code
RespInfo1/Response Information 1
RespInfo2/Response Information 2
RespData/Response Data
Multi-Reader/Writer Mode
Number of Slave Reader/Writers
IP Address of Slave Reader/
Writer No. 1
IP Address of Slave Reader/
Writer No. 2
IP Address of Slave Reader/
Writer No. 3
IP Address of Slave Reader/
Writer No. 4
IP Address of Slave Reader/
Writer No. 5
IP Address of Slave Reader/
Writer No. 6
IP Address of Slave Reader/
Writer No. 7
RFID System
126
User's Manual
(PROFINET)
Signal/data
Data type
WORD
WORD
WORD
Signal/data
Data type
WORD
WORD
WORD
WORD
WORD
DWORD
DWORD
DWORD
DWORD
DWORD
DWORD
DWORD
Size
2 bytes
1004 hex
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
Size
2 bytes
Error code
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
0000 hex: Disable
2 bytes
0001 hex: Enable Field Extension Mode
0002 hex: Enable High-speed Traveling Mode
Number of Reader/Writers linked with multi-Reader/
2 bytes
Writer operation
0000 to 0007 hex
IP addresses of Slave Reader/Writers
4 bytes
0000 0000 to FFFF FFFF hex
4 bytes
Example: C0A801C8 hex (192.168.1.200)
4 bytes
4 bytes
4 bytes
4 bytes
4 bytes
Function