Section 5
Host Communications Specifications
 Command Errors
Error code name
Unknown command error
Command parameter error
Execution status error
 RF Tag Communications Errors
Error code name
RF Tag missing error
RF Tag communications error
UID mismatch error
RF Tag address error
RF Tag lock error
Verification error
RF Tag data lost error
RF Tag system error
RF Tag overwriting error
Reader/Writer connection error
Communications connection
error between Reader/Writers
 Reader/Writer Operation Errors
Error code name
Unfixed operation mode error
User setting error
Multi-Reader/Writer execution
error
RFID System
110
User's Manual
(PROFINET)
Error code
1003 hex
A command that is not supported by the Reader/Writer was received.
1005 hex
There was an error in the parameters in the received command data.
1006 hex
The Reader/Writer could not execute the command that was received.
Error code
2001 hex
There is no RF Tag in the communications field.
2002 hex
Communications with the RF Tag did not end normally.
2003 hex
An RF Tag with the specified ID was not in the communications field.
The access address for the RF Tag is outside of the area supported by
2004 hex
the target RF Tag.
2005 hex
An attempt was made to write data to a locked area.
2006 hex
Processing to write data to the RF Tag did not end normally.
Processing to write data to the RF Tag did not end normally. (Data may
2007 hex
have been lost and must be restored.)
2008 hex
The RF Tag returned an error response.
2009 hex
The overwrite limit was exceeded for overwrite count control processing.
When executing the COPY DATA command, communications could not
200A hex
be established with the copy destination Reader/Writer.
When executing multi-Reader/Writer functions, communications could
200B hex
not be established with a Slave Reader/Writer.
Error code
The control signal was not stable when the Reader/Writer was started. A
8001 hex
record is stored only in the system error log.
An error was detected in user configuration memory when the Reader/
Writer was started. A record is stored only in the system error log.
The classification of the setting is given in attached information 1.
8002 hex
0000 0001 hex: Network setting
0000 0002 hex: RF Tag communications setting
0000 0003 hex: Multi-Reader/Writer setting
A set value was detected when the Reader/Writer was started that
prevents execution of multi-Reader/Writer operation.
The reason for the error is given in attached information 1.
8003 hex
0000 0001 hex: The combination of the Multi-Reader/Writer Mode and
the communications option prevented execution.
0000 0002 hex: This Reader/Writer has the same IP address as the
Slave Reader/Writer.
Description
Description
Description